Investigation of a four-wave mixing signal generated in fiber-delivered CARS microscopy
- PMID: 20648166
- DOI: 10.1364/AO.49.003916
Investigation of a four-wave mixing signal generated in fiber-delivered CARS microscopy
Abstract
We studied the nonlinear signal generated in the fiber at an anti-Stokes wavelength during the delivery of the picosecond (ps) pump and Stokes beams in coherent anti-Stokes Raman scattering (CARS) microscopy. A small non-phase-matched four-wave mixing (FWM) signal was prevalently observed in the fiber at the power level where other nonlinear processes, including self-phase modulation and cross-phase modulation, were well suppressed. We analyzed the features of the FWM signal generation by varying the location of temporal overlap between two input pulses in the fiber to compare this to the CARS signal generated in the sample. Numerical modeling based on the nonlinear Schrödinger equation was also conducted and clearly explains the results in the experiment. In addition, we experimentally verified the interferometric feature of this FWM signal with the CARS signal by employing a phase-shifting unit, which potentially suggests the use of the FWM signal as a local oscillator for the interferometric CARS system.
Similar articles
-
Delivery of picosecond lasers in multimode fibers for coherent anti-Stokes Raman scattering imaging.Opt Express. 2010 Jun 7;18(12):13017-28. doi: 10.1364/OE.18.013017. Opt Express. 2010. PMID: 20588430
-
Coherent anti-Stokes Raman scattering microscopy imaging with suppression of four-wave mixing in optical fibers.Opt Express. 2011 Apr 25;19(9):7960-70. doi: 10.1364/OE.19.007960. Opt Express. 2011. PMID: 21643045
-
Use of multimode optical fibers for fiber-based coherent anti-Stokes Raman scattering microendoscopy imaging.Opt Lett. 2011 Aug 1;36(15):2967-9. doi: 10.1364/OL.36.002967. Opt Lett. 2011. PMID: 21808374
-
Raman microscopy based on doubly-resonant four-wave mixing (DR-FWM).Opt Express. 2009 Sep 14;17(19):17044-51. doi: 10.1364/OE.17.017044. Opt Express. 2009. PMID: 19770922
-
Fiber-format CARS spectroscopy by spectral compression of femtosecond pulses from a single laser oscillator.Opt Lett. 2009 Nov 1;34(21):3262-4. doi: 10.1364/OL.34.003262. Opt Lett. 2009. PMID: 19881561
Cited by
-
Advances in engineering of high contrast CARS imaging endoscopes.Opt Express. 2014 Oct 20;22(21):25053-64. doi: 10.1364/OE.22.025053. Opt Express. 2014. PMID: 25401538 Free PMC article.
-
Multimodal nonlinear endomicroscopic imaging probe using a double-core double-clad fiber and focus-combining micro-optical concept.Light Sci Appl. 2021 Oct 5;10(1):207. doi: 10.1038/s41377-021-00648-w. Light Sci Appl. 2021. PMID: 34611136 Free PMC article.
-
Intact primate brain tissue identification using a completely fibered coherent Raman spectroscopy system.Neurophotonics. 2018 Jul;5(3):035005. doi: 10.1117/1.NPh.5.3.035005. Epub 2018 Aug 17. Neurophotonics. 2018. PMID: 30137924 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources