Evaluation of Quadrox-i adult hollow fiber oxygenator with integrated arterial filter
- PMID: 20648898
- PMCID: PMC4680037
Evaluation of Quadrox-i adult hollow fiber oxygenator with integrated arterial filter
Abstract
Gaseous microemboli (GME) remain a challenge for cardiopulmonary bypass procedures in adult as well as pediatric cardiac surgery patients. The present study tested the effectiveness of a new adult membrane oxygenator in models both with and without an integrated arterial filter to evaluate GME trapping capability and determine membrane pressure drops at various flow rates and temperatures. The experimental circuit included a RotaFlow centrifugal blood pump, Quadrox-i (n = 8) or Quadrox (n = 8) adult microporous membrane oxygenator, and Sorin adult tubing package. A Sorin Cardiovascular VVR 4000i venous reservoir served as pseudo-patient. The circuit was primed with 900 mL heparinized human red blood cells and 300 mL Lactated Ringer's solution. The final hematocrit was 36%. Tests were performed at different flow rates (4 L/min, 5 L/min, and 6 L/min) and temperatures (35 degrees and 30 degrees). Five mL of bolus air was injected into the venous line over 15 seconds using a syringe connected to a 3/8 x 1/2 luer connector. The Quadrox-i adult microporous membrane oxygenator with integrated arterial filter had a similar pressure drop at 4 L/min and 35 degrees C compared with Quadrox membrane oxygenator whereas it had higher pressure drops at 5 L/min and 6 L/min (p < .001). Quadrox-i adult microporous membrane oxygenator reduced the total emboli count and total emboli volume delivered to the pseudo-patient at all flow rates (p < .001).The emboli handling of Quadrox-i adult microporous membrane oxygenator was not affected by flow rate and temperature. Compared with the traditional Quadrox oxygenator, Quadrox-i adult microporous membrane oxygenator with integrated arterial filter and Softline coating has improved GME handling capacity.
Conflict of interest statement
The senior author has stated that authors have reported no material, financial, or other relationship with any healthcare-related business or other entity whose products or services are discussed in this paper.
Figures
Comment in
-
Evaluation of Quadrox-i adult hollow fiber oxygenator with integrated arterial filter.J Extra Corpor Technol. 2010 Sep;42(3):242; author reply 243. J Extra Corpor Technol. 2010. PMID: 21114230 Free PMC article. No abstract available.
References
-
- Al-Rashidi F, Blomquist S, Höglund P, Meurling C, Roijer A, Koul B.. A new de-airing technique that reduces systemic microemboli during open surgery: A prospective controlled study. J Thorac Cardiovasc Surg. 2009;138:157–62. - PubMed
-
- Prasongsukarn K, Borger MA.. Reducing cerebral emboli during cardiopulmonary bypass. Semin Cardiothorac Vasc Anesth. 2005;9:153–8. - PubMed
-
- Perthel M, Kseibi S, Bendisch A, Laas J.. Use of a dynamic bubble trap in the arterial line reduces microbubbles during cardiopulmonary bypass and microembolic signals in the middle cerebral artery. Perfusion. 2005;20:151–6. - PubMed
-
- Schreiner RS, Rider AR, Myers JW, et al. . Microemboli detection and classification by innovative ultrasound technology during simulated neonatal cardiopulmonary bypass at different flow rates, perfusion modes, and perfusate temperatures. ASAIO J. 2008;54:316–24. - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources