Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2010 Jul;3(7):742-50.
doi: 10.1016/j.jcin.2010.04.012.

Outcomes after implantation of the TAXUS paclitaxel-eluting stent in saphenous vein graft lesions: results from the ARRIVE (TAXUS Peri-Approval Registry: A Multicenter Safety Surveillance) program

Affiliations
Free article
Multicenter Study

Outcomes after implantation of the TAXUS paclitaxel-eluting stent in saphenous vein graft lesions: results from the ARRIVE (TAXUS Peri-Approval Registry: A Multicenter Safety Surveillance) program

Emmanouil S Brilakis et al. JACC Cardiovasc Interv. 2010 Jul.
Free article

Abstract

Objectives: The aim of this study was to examine the incidence of clinical events after implantation of the TAXUS Express (Boston Scientific Corporation, Natick, Massachusetts) paclitaxel-eluting stent in saphenous vein graft (SVG) lesions in an unselected patient population.

Background: Saphenous vein grafts have 1-year occlusion rates of 12% to 20%, with >50% failure by 7 to 10 years. Many diseased SVGs are treated by percutaneous coronary intervention to avoid higher-risk reoperation, but bare-metal stents have 35% to 40% historical SVG restenosis rates by 18 months. Reported outcomes of drug-eluting stents in SVG lesions are limited and mainly retrospective.

Methods: The ARRIVE (TAXUS Peri-Approval Registry: A Multicenter Safety Surveillance) program compiled data on 7,492 patients receiving > or =1 TAXUS Express (Boston Scientific) stent, including 474 patients with SVG. All cardiac events were monitored with independent adjudication of end points. Patients enrolled at procedure start with no mandated inclusion/exclusion criteria.

Results: The ARRIVE SVG patient 2-year follow-up was 96% complete (457 of 474). The SVG patients had significantly more baseline comorbidities/complex disease than simple-use patients (n = 2,698) undergoing native coronary intervention or other expanded-use patients (n = 4,320 without SVG patients). They had higher 2-year rates of mortality (10.9% vs. 4.2%, p < 0.001), myocardial infarction (5.3% vs. 2.2%, p < 0.001), and Academic Research Consortium definite/probable stent thrombosis (4.7% vs. 1.4%, p < 0.001) than the simple-use group. They also had higher 2-year adverse event rates, including significantly more mortality (10.9% vs. 7.5%, p = 0.008) than other expanded-use patients.

Conclusions: The ARRIVE SVG patients have significantly different baseline risk and higher clinical risk through 2 years than simple-use and other expanded-use patients. Nonetheless, compared with historical SVG revascularization rates, treatment with paclitaxel-eluting stent seems to offer a reasonable therapeutic option in this high-risk group. (TAXUS ARRIVE: TAXUS Peri-Approval Registry: A Multicenter Safety Surveillance Program; NCT00569491) and (TAXUS ARRIVE 2: A Multicenter Safety Surveillance Program; NCT00569751).

PubMed Disclaimer

Publication types

MeSH terms

Associated data