Improved detection limits of toxic biochemical species based on impedance measurements in electrochemical biosensors
- PMID: 20655726
- DOI: 10.1016/j.bios.2010.06.051
Improved detection limits of toxic biochemical species based on impedance measurements in electrochemical biosensors
Abstract
An impedance based electrochemical biosensor was designed and fabricated for the detection of various chemical and biological species, with glass as substrate material and gold interdigitated electrodes. A flow cell with inlet and outlet ports for the microfluidic chamber was designed and fabricated using acrylic material with a reservoir volume of 78 μl. The feasibility of the fabricated sensor for detecting very low concentration of chemical and biological species was demonstrated. Electrochemical impedance spectroscopy (EIS) was employed as the detection technique. The impedance based response of the two-terminal device revealed a very high sensitivity with low concentrations of mouse monoclonal IgG, sarcosine, cadmium sulphide (CdS) and potassium chloride (KCl) at pico mole levels.
Copyright © 2010 Elsevier B.V. All rights reserved.
Similar articles
-
Electrochemical impedance spectroscopy biosensor with interdigitated electrode for detection of human immunoglobulin A.Biosens Bioelectron. 2013 Feb 15;40(1):422-6. doi: 10.1016/j.bios.2012.07.052. Epub 2012 Aug 10. Biosens Bioelectron. 2013. PMID: 22917917
-
Construction of DNA biosensor at glassy carbon surface modified with 4-aminoethylbenzenediazonium salt.Biosens Bioelectron. 2011 Jan 15;26(5):2506-12. doi: 10.1016/j.bios.2010.10.046. Epub 2010 Oct 31. Biosens Bioelectron. 2011. PMID: 21112202
-
Impedimetric aptasensor for tobramycin detection in human serum.Biosens Bioelectron. 2011 Jan 15;26(5):2354-60. doi: 10.1016/j.bios.2010.10.011. Epub 2010 Oct 14. Biosens Bioelectron. 2011. PMID: 21051217
-
Interdigitated array microelectrodes based impedance biosensors for detection of bacterial cells.Biosens Bioelectron. 2009 Jun 15;24(10):2951-60. doi: 10.1016/j.bios.2008.10.001. Epub 2008 Oct 17. Biosens Bioelectron. 2009. PMID: 19041235 Review.
-
Dielectric spectroscopy as a viable biosensing tool for cell and tissue characterization and analysis.Biosens Bioelectron. 2013 Nov 15;49:348-59. doi: 10.1016/j.bios.2013.04.017. Epub 2013 May 15. Biosens Bioelectron. 2013. PMID: 23796534 Review.
Cited by
-
Bio- and Biomimetic Receptors for Electrochemical Sensing of Heavy Metal Ions.Sensors (Basel). 2020 Nov 28;20(23):6800. doi: 10.3390/s20236800. Sensors (Basel). 2020. PMID: 33260737 Free PMC article. Review.
-
Advantages of imprinted polymer electrodes for electrochemical pathogen detection.Curr Opin Electrochem. 2022 Dec;36:101123. doi: 10.1016/j.coelec.2022.101123. Epub 2022 Aug 24. Curr Opin Electrochem. 2022. PMID: 40893461 Free PMC article.
-
Future opportunities for advancing glucose test device electronics.J Diabetes Sci Technol. 2011 Sep 1;5(5):1077-86. doi: 10.1177/193229681100500508. J Diabetes Sci Technol. 2011. PMID: 22027300 Free PMC article.
-
A Comprehensive Review: Development of Electrochemical Biosensors for Detection of Cyanotoxins in Freshwater.ACS Sens. 2019 May 24;4(5):1151-1173. doi: 10.1021/acssensors.9b00376. Epub 2019 May 14. ACS Sens. 2019. PMID: 31056912 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources