Sensitivity of five rapid HIV tests on oral fluid or finger-stick whole blood: a real-time comparison in a healthcare setting
- PMID: 20657834
- PMCID: PMC2906506
- DOI: 10.1371/journal.pone.0011581
Sensitivity of five rapid HIV tests on oral fluid or finger-stick whole blood: a real-time comparison in a healthcare setting
Abstract
Background: Health authorities in several countries recently recommended the expansion of human immunodeficiency virus (HIV) antibody testing, including the use of rapid tests. Several HIV rapid tests are now licensed in Europe but their sensitivity on total blood and/or oral fluid in routine healthcare settings is not known.
Methods and findings: 200 adults with documented HIV-1 (n=194) or HIV-2 infection (n=6) were prospectively screened with five HIV rapid tests using either oral fluid (OF) or finger-stick whole blood (FSB). The OraQuick Advance rapid HIV1/2 was first applied to OF and then to FSB, while the other tests were applied to FSB, in the following order: Vikia HIV 1/2, Determine HIV 1-2, Determine HIV-1/2 Ag/Ab Combo and INSTI HIV-1/HIV-2. Tests negative on FSB were repeated on paired serum samples. Twenty randomly selected HIV-seronegative subjects served as controls, and the results were read blindly. Most patients had HIV-1 subtype B infection (63.3%) and most were on antiretroviral therapy (68.5%). Sensitivity was 86.5%, 94.5%, 98.5%, 94.9%, 95.8% and 99% respectively, with OraQuick OF, OraQuick FSB, Vikia, Determine, Determine Ag/Ab Combo and INSTI (p<0.0001). OraQuick was less sensitive on OF than on FSB (p=0.008). Among the six patients with three or more negative tests, two had recent HIV infection and four patients on antiretroviral therapy had undetectable plasma viral load. When patients positive in all the tests were compared with patients who had at least one negative test, only a plasma HIV RNA level<200 cp/ml was significantly associated with a false-negative result (p=0.009). When the 33 rapid tests negative on FSB were repeated on serum, all but six (5 negative with OraQuick, 1 with INSTI) were positive. The sensitivity of OraQuick, Determine and Determine Ag/Ab Combo was significantly better on serum than on FSB (97.5%, p=0.04; 100%, p=0.004; and 100%, p=0.02, respectively).
Conclusion: When evaluated in a healthcare setting, rapid HIV tests were less sensitive on oral fluid than on finger-stick whole blood and less sensitive on finger-stick whole blood than on serum.
Conflict of interest statement
Similar articles
-
Finger-stick whole blood HIV-1/-2 home-use tests are more sensitive than oral fluid-based in-home HIV tests.PLoS One. 2014 Jun 27;9(6):e101148. doi: 10.1371/journal.pone.0101148. eCollection 2014. PLoS One. 2014. PMID: 24971842 Free PMC article.
-
Evaluation of diagnostic accuracy, feasibility and client preference for rapid oral fluid-based diagnosis of HIV infection in rural India.PLoS One. 2007 Apr 11;2(4):e367. doi: 10.1371/journal.pone.0000367. PLoS One. 2007. PMID: 17426815 Free PMC article.
-
False-positive oral fluid rapid HIV tests--New York City, 2005-2008.MMWR Morb Mortal Wkly Rep. 2008 Jun 20;57(24):660-5. MMWR Morb Mortal Wkly Rep. 2008. PMID: 18566566
-
[Screening tests combined with p24 antigen and anti-HIV antibodies in early detection of HIV-1].Transfus Clin Biol. 2000 Jun;7 Suppl 1:18s-24s. doi: 10.1016/s1246-7820(00)80011-7. Transfus Clin Biol. 2000. PMID: 10919219 Review. French.
-
[Serology of HIV infection].Hautarzt. 1989 Dec;40(12):745-51. Hautarzt. 1989. PMID: 2695498 Review. German.
Cited by
-
De-medicalized and decentralized HIV testing: a strategy to test hard-to-reach men who have sex with men in Cameroon.Front Public Health. 2023 Jul 26;11:1180813. doi: 10.3389/fpubh.2023.1180813. eCollection 2023. Front Public Health. 2023. PMID: 37564422 Free PMC article.
-
Point-of-Care Diagnostics for Improving Maternal Health in South Africa.Diagnostics (Basel). 2016 Aug 31;6(3):31. doi: 10.3390/diagnostics6030031. Diagnostics (Basel). 2016. PMID: 27589808 Free PMC article. Review.
-
Identifying HIV infection in South African women: How does a fourth generation HIV rapid test perform?Afr J Lab Med. 2011 Dec 15;1(1):4. doi: 10.4102/ajlm.v1i1.4. eCollection 2012. Afr J Lab Med. 2011. PMID: 29062724 Free PMC article.
-
HIV Diagnosis and Treatment through Advanced Technologies.Front Public Health. 2017 Mar 7;5:32. doi: 10.3389/fpubh.2017.00032. eCollection 2017. Front Public Health. 2017. PMID: 28326304 Free PMC article. Review.
-
Performance evaluation of the point-of-care INSTI™ HIV-1/2 antibody test in early and established HIV infections.J Clin Virol. 2017 Jun;91:90-94. doi: 10.1016/j.jcv.2017.03.012. Epub 2017 Mar 23. J Clin Virol. 2017. PMID: 28372890 Free PMC article.
References
-
- Losina E, Schackman BR, Sadownik SN, Gebo KA, Walensky RP, et al. Racial and Sex Disparities in Life Expectancy Losses among HIV-Infected Persons in the United States: Impact of Risk Behavior, Late Initiation, and Early Discontinuation of Antiretroviral Therapy. Clin Infect Dis. 2009;49:1570–1578. - PMC - PubMed
-
- Hamers FF, Phillips AN. Diagnosed and undiagnosed HIV infected populations in Europe. HIV Med 9. 2008;(Suppl 2):6–12. - PubMed
-
- Delpierre C, Cuzin L, Lauwers-Cances V, Marchou B, Lang T, et al. High-Risk groups for late diagnosis of HIV infection: a need for rethinking testing policy in the general population. AIDS Patient care STDs. 2006;20:838–847. - PubMed
-
- Braitstein P, Brinkhof MW, Dabis F, Schechter M, Boulle A, et al. Mortality of HIV-1-infected patients in the first year of antiretroviral therapy: comparison between low-income and high-income countries. Lancet. 2006;367:817–824. - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials
Miscellaneous