A novel method for angle independent ultrasonic imaging of blood flow and tissue motion
- PMID: 2066142
- DOI: 10.1109/10.133210
A novel method for angle independent ultrasonic imaging of blood flow and tissue motion
Abstract
Tracking the speckle patterns produced by moving targets has been shown effective for angle independent imaging of blood flow and tissue motion. While speckle tracking overcomes major limitations of Doppler-based flow imaging, the computational complexity of commonly used cross correlation algorithms currently limits it to off-line studies. A much simpler algorithm for angle independent motion imaging is described in this paper. This method requires only one absolute difference operation per pixel, compared to eight operations for normalized cross correlation. Quantitative studies using speckle-generating targets translated by fixed amounts both axially and laterally indicate that the technique tracks moving speckle as accurately as correlation. Color flow images generated from clinical blood and liver data highlight the success of the technique for tracking both large and small motions in two dimensions. The algorithm's suitability for implementation in digital hardware makes possible the development of clinical instruments for angle independent ultrasonic imaging of blood flow and tissue motion in real time.
Similar articles
-
Comparison of myocardial tissue velocities measured by two-dimensional speckle tracking and tissue Doppler imaging.Am J Cardiol. 2008 Sep 15;102(6):784-9. doi: 10.1016/j.amjcard.2008.05.027. Epub 2008 Jul 10. Am J Cardiol. 2008. PMID: 18774007
-
Motion estimation in ultrasound images using time domain cross correlation with prior estimates.IEEE Trans Biomed Eng. 2006 Oct;53(10):1990-2000. doi: 10.1109/TBME.2006.881780. IEEE Trans Biomed Eng. 2006. PMID: 17019863
-
Doppler color imaging. Principles and instrumentation.Clin Diagn Ultrasound. 1992;27:7-60. Clin Diagn Ultrasound. 1992. PMID: 1497942 Review.
-
Radial strain and strain rate by two-dimensional speckle tracking echocardiography and the tissue velocity based technique in the dog.J Vet Cardiol. 2007 Nov;9(2):69-81. doi: 10.1016/j.jvc.2006.11.002. Epub 2007 Nov 26. J Vet Cardiol. 2007. PMID: 18037363
-
Recent advances in carotid artery evaluation.Clin Diagn Ultrasound. 1990;26:25-44. Clin Diagn Ultrasound. 1990. PMID: 2182090 Review.
Cited by
-
Quantitative assessment of tumor angiogenesis using real-time motion-compensated contrast-enhanced ultrasound imaging.Angiogenesis. 2012 Sep;15(3):433-42. doi: 10.1007/s10456-012-9271-3. Epub 2012 Apr 26. Angiogenesis. 2012. PMID: 22535383 Free PMC article.
-
Cardiac magnetic resonance imaging in the assessment of cardiac injury and toxicity from cancer-related chemotherapy.Pediatr Radiol. 2025 Jun 9. doi: 10.1007/s00247-025-06260-z. Online ahead of print. Pediatr Radiol. 2025. PMID: 40488773 Review.
-
Tendon motion and strain patterns evaluated with two-dimensional ultrasound elastography.J Biomech. 2012 Oct 11;45(15):2618-23. doi: 10.1016/j.jbiomech.2012.08.001. Epub 2012 Aug 28. J Biomech. 2012. PMID: 22939179 Free PMC article.
-
Left ventricular strain and untwist in hypertrophic cardiomyopathy: relation to exercise capacity.Am Heart J. 2010 May;159(5):825-32. doi: 10.1016/j.ahj.2010.02.002. Am Heart J. 2010. PMID: 20435192 Free PMC article.
-
Exploration of the Utility of Speckle-Tracking Echocardiography During Mechanical Ventilation and Mechanical Circulatory Support.Crit Care Explor. 2022 Mar 30;4(4):e0666. doi: 10.1097/CCE.0000000000000666. eCollection 2022 Apr. Crit Care Explor. 2022. PMID: 35372843 Free PMC article. Review.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources