Pulse pressure analysis: to make a long story short
- PMID: 20663181
- PMCID: PMC2945074
- DOI: 10.1186/cc9065
Pulse pressure analysis: to make a long story short
Abstract
Pulse pressure analysis algorithms are commonly used to measure cardiac output and to allow for the rational titration of therapy in critically ill patients. The ability of these algorithms to accurately track changes in stroke volume (and cardiac output) is thus very important. Most of the currently available algorithms can provide robust data so long as there is no fundamental change in the vasomotor tone (arterial compliance or impedance). If the tone changes significantly, for instance with vasodilatation or vasoconstriction, then the data become less robust. For this reason, unless there is a mechanism for compensating for changes in vasomotor tone, these algorithms are best used only over short time periods in order to get the most accurate and precise data on changes in cardiac output.
Comment on
-
Arterial pressure-based cardiac output in septic patients: different accuracy of pulse contour and uncalibrated pressure waveform devices.Crit Care. 2010;14(3):R109. doi: 10.1186/cc9058. Epub 2010 Jun 10. Crit Care. 2010. PMID: 20537159 Free PMC article.
Similar articles
-
Cardiac output estimation using pulse wave analysis-physiology, algorithms, and technologies: a narrative review.Br J Anaesth. 2021 Jan;126(1):67-76. doi: 10.1016/j.bja.2020.09.049. Epub 2020 Nov 24. Br J Anaesth. 2021. PMID: 33246581 Review.
-
Edwards FloTrac sensor and Vigileo monitor: easy, accurate, reliable cardiac output assessment using the arterial pulse wave.Expert Rev Med Devices. 2005 Sep;2(5):523-7. doi: 10.1586/17434440.2.5.523. Expert Rev Med Devices. 2005. PMID: 16293062 Review.
-
Arterial pressure-based cardiac output in septic patients: different accuracy of pulse contour and uncalibrated pressure waveform devices.Crit Care. 2010;14(3):R109. doi: 10.1186/cc9058. Epub 2010 Jun 10. Crit Care. 2010. PMID: 20537159 Free PMC article.
-
Cardiac output by pulse contour analysis does not match the increase measured by rebreathing during human spaceflight.J Appl Physiol (1985). 2017 Nov 1;123(5):1145-1149. doi: 10.1152/japplphysiol.00651.2017. Epub 2017 Aug 10. J Appl Physiol (1985). 2017. PMID: 28798205 Free PMC article.
-
Arterial pressure-based technologies: a new trend in cardiac output monitoring.Crit Care Nurs Clin North Am. 2006 Jun;18(2):179-87, x. doi: 10.1016/j.ccell.2006.01.004. Crit Care Nurs Clin North Am. 2006. PMID: 16728303 Review.
Cited by
-
Multimorbidity and Critical Care Neurosurgery: Minimizing Major Perioperative Cardiopulmonary Complications.Neurocrit Care. 2021 Jun;34(3):1047-1061. doi: 10.1007/s12028-020-01072-5. Epub 2020 Aug 13. Neurocrit Care. 2021. PMID: 32794145 Free PMC article. Review.
-
Pavane for a pulse pressure variation defunct.Crit Care. 2013 Nov 14;17(6):327. doi: 10.1186/cc13109. Crit Care. 2013. PMID: 24229428 Free PMC article.
-
Impact of arterial load on the agreement between pulse pressure analysis and esophageal Doppler.Crit Care. 2013 Jun 20;17(3):R113. doi: 10.1186/cc12785. Crit Care. 2013. PMID: 23787086 Free PMC article.
-
Cardiac output obtained by pulse pressure analysis: to calibrate or not to calibrate may not be the only question when used properly.Intensive Care Med. 2013 Apr;39(4):787-9. doi: 10.1007/s00134-012-2802-y. Epub 2013 Jan 4. Intensive Care Med. 2013. PMID: 23287877 No abstract available.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources