Pseudotumor in large-diameter metal-on-metal total hip articulation
- PMID: 20663635
- DOI: 10.1016/j.arth.2010.05.022
Pseudotumor in large-diameter metal-on-metal total hip articulation
Abstract
Large-diameter metal-on-metal hip arthroplasties have incited renewed interest because of the advantages of decreased wear and increased stability. These new designs have not had significant long-term or midterm performance results, and we are reporting the case of pseudotumor in a patient with a painful metal-on-metal hip arthroplasty.
Copyright © 2011 Elsevier Inc. All rights reserved.
Similar articles
-
High incidence of pseudotumour formation after large-diameter metal-on-metal total hip replacement: a prospective cohort study.J Bone Joint Surg Br. 2012 Jun;94(6):755-61. doi: 10.1302/0301-620X.94B6.28373. J Bone Joint Surg Br. 2012. PMID: 22628588 Clinical Trial.
-
Inflammatory pseudotumor complicating metal-on-highly cross-linked polyethylene total hip arthroplasty.J Arthroplasty. 2012 Feb;27(2):324.e5-8. doi: 10.1016/j.arth.2011.03.013. Epub 2011 Apr 16. J Arthroplasty. 2012. PMID: 21498036
-
Failure of larger-diameter metal-on-metal total hip arthroplasty resulting from anterior iliopsoas impingement.J Arthroplasty. 2011 Sep;26(6):978.e5-8. doi: 10.1016/j.arth.2010.10.002. Epub 2010 Dec 4. J Arthroplasty. 2011. PMID: 21130601
-
Use of modular large femoral heads without liners in hip arthroplasty.Surg Technol Int. 2006;15:217-20. Surg Technol Int. 2006. PMID: 17029179 Review.
-
Diagnosing and investigating adverse reactions in metal on metal hip implants.BMJ. 2011 Nov 29;343:d7441. doi: 10.1136/bmj.d7441. BMJ. 2011. PMID: 22127518 Review. No abstract available.
Cited by
-
Polyethylene and metal wear particles: characteristics and biological effects.Semin Immunopathol. 2011 May;33(3):257-71. doi: 10.1007/s00281-011-0242-3. Epub 2011 Jan 26. Semin Immunopathol. 2011. PMID: 21267569 Review.
-
Adverse Reactions to Metal on Metal Are Not Exclusive to Large Heads in Total Hip Arthroplasty.Clin Orthop Relat Res. 2016 Feb;474(2):432-40. doi: 10.1007/s11999-015-4539-8. Clin Orthop Relat Res. 2016. PMID: 26497881 Free PMC article.
-
The 2012 John Charnley Award: Clinical multicenter studies of the wear performance of highly crosslinked remelted polyethylene in THA.Clin Orthop Relat Res. 2013 Feb;471(2):393-402. doi: 10.1007/s11999-012-2604-0. Clin Orthop Relat Res. 2013. PMID: 23070661 Free PMC article.
-
Large-diameter metal-on-metal total hip arthroplasty: dislocation infrequent but survivorship poor.Clin Orthop Relat Res. 2015 Feb;473(2):509-20. doi: 10.1007/s11999-014-3976-0. Epub 2014 Nov 4. Clin Orthop Relat Res. 2015. PMID: 25367107 Free PMC article.
-
Formation of a pseudotumor in total hip arthroplasty using a tribological metal-polyethylene pair.Rev Bras Ortop. 2015 Oct 19;50(6):747-51. doi: 10.1016/j.rboe.2015.10.006. eCollection 2015 Nov-Dec. Rev Bras Ortop. 2015. PMID: 27218090 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical