Outcome of opening wedge high tibial osteotomy augmented with a Biosorb® wedge and fixed with a plate and screws in 124 patients with a mean of ten years follow-up
- PMID: 20668849
- PMCID: PMC3167423
- DOI: 10.1007/s00264-010-1102-9
Outcome of opening wedge high tibial osteotomy augmented with a Biosorb® wedge and fixed with a plate and screws in 124 patients with a mean of ten years follow-up
Abstract
The objective of this work was firstly to evaluate the long-term results of medial opening wedge high tibial osteotomy (HTO) and secondly to evaluate the tolerance and integration of a Biosorb® wedge (β Tricalcium Phosphate, SBM Company, Lourdes, France). The series consisted of 124 knees in 110 patients, 74 men and 36 women, with mean age of 53.23±10.68 years (range 32-74) and treated between June 1995 and November 2000 for medial compartment knee osteoarthritis by the senior author. The mean preoperative Lysholm and Tegner functional score was 65.44±13.32 (range 27-80) and the preoperative HKA angle was 172.51°±3.8° (range 162-179°). According to the modified Ahlbäck classification there were 27 stage I, 42 stage II, 44 stage III and 11 stage IV knees. All patients were reviewed clinically and radiologically with a mean follow-up of 10.39±1.98 years (range 8-14 years). Immediate postoperative complications consisted of nine undisplaced lateral tibial plateau fractures of no clinical significance, two deep vein thromboses and three pulmonary emboli which resolved with appropriate treatment. At a later stage, there were seven delayed unions without development of pseudarthrosis, and three screw breakages when the AO T-plate was used, leading to a secondary angulation in one case, requiring revision by femoral osteotomy. Postoperative mean weightbearing HKA angle was 182°±1.8° (range 178-186°) and 73.4% of axes were 184°±2°. Fifteen knees (12.1%) underwent total knee arthroplasty (TKA) after a mean delay of 8.87±3.04 years and were excluded from the final analysis. Concerning the long-term results (n = 107 knees), the mean Lysholm-Tegner score was 88±12.7 points (51-100) and the KOOS score was 86±14.6 points (25-100) with 94 patients satisfied or very satisfied (87.85%). In terms of the HTO survivorship curve, with failure consisting of revision to TKA or another operation, survival was 88.8% at five years and 74% at ten years. Concerning Biosorb®, this was completely integrated in 100% of cases and there was complete resorption in 12.1% of cases and greater than 50% resorption in 52.3% of cases.
Figures
Similar articles
-
Computer-assisted osteotomy for valgus knees: medium-term results of 29 cases.Orthop Traumatol Surg Res. 2014 Sep;100(5):527-30. doi: 10.1016/j.otsr.2014.04.002. Epub 2014 Jul 30. Orthop Traumatol Surg Res. 2014. PMID: 25087004
-
Computer-assisted total knee replacement after medial opening wedge high tibial osteotomy: medium-term results in a series of ninety cases.Int Orthop. 2016 Jan;40(1):35-40. doi: 10.1007/s00264-015-2791-x. Epub 2015 May 7. Int Orthop. 2016. PMID: 25947901
-
Short-Term Clinical Outcomes of High Tibial Osteotomy with the iBalance HTO System.Bull Hosp Jt Dis (2013). 2019 Dec;77(4):256-262. Bull Hosp Jt Dis (2013). 2019. PMID: 31785139
-
Total knee arthroplasty post-high tibial osteotomy, results of an early experience from a North African arthroplasty unit, and a comprehensive review of the literature.J Orthop Surg Res. 2023 Sep 20;18(1):705. doi: 10.1186/s13018-023-04199-1. J Orthop Surg Res. 2023. PMID: 37730629 Free PMC article. Review.
-
Return to Work and Sport Following High Tibial Osteotomy: A Systematic Review.J Bone Joint Surg Am. 2016 Sep 21;98(18):1568-77. doi: 10.2106/JBJS.16.00036. J Bone Joint Surg Am. 2016. PMID: 27655985
Cited by
-
Full weight bearing and dynamisation with Limmed® locked plate fixation accelerates bone regeneration in the volume of opening wedge high tibial osteotomy.Int Orthop. 2015 Jul;39(7):1295-300. doi: 10.1007/s00264-014-2633-2. Epub 2014 Dec 24. Int Orthop. 2015. PMID: 25532861
-
Osteotomy around the knee: evolution, principles and results.Knee Surg Sports Traumatol Arthrosc. 2013 Jan;21(1):3-22. doi: 10.1007/s00167-012-2206-0. Epub 2012 Sep 29. Knee Surg Sports Traumatol Arthrosc. 2013. PMID: 23052110
-
Comparative study of medial opening wedge high tibial osteotomy using fixator-cum-distractor device or locking plate in medial unicompartmental osteoarthritis of knee.J Clin Orthop Trauma. 2020 Feb;11(Suppl 1):S137-S141. doi: 10.1016/j.jcot.2019.07.005. Epub 2019 Jul 16. J Clin Orthop Trauma. 2020. PMID: 31992934 Free PMC article.
-
Satisfactory long-term survival, functional and radiological outcomes of open-wedge high tibial osteotomy for managing knee osteoarthritis: Minimum 10-year follow-up study.J Orthop Translat. 2020 Mar 30;26:60-66. doi: 10.1016/j.jot.2020.03.003. eCollection 2021 Jan. J Orthop Translat. 2020. PMID: 33437624 Free PMC article.
-
A New Preoperative Planning Technique Can Reduce Radiation Exposure During the Performance of Medial Opening-Wedge High Tibial Osteotomy.HSS J. 2018 Oct;14(3):251-257. doi: 10.1007/s11420-017-9591-3. Epub 2017 Dec 26. HSS J. 2018. PMID: 30258329 Free PMC article.
References
-
- Aglietti P, Buzzi R, Vena LM, Baldini A, Mondaini A. High tibial valgus osteotomy for medial gonarthrosis : a 10 to 21-year study. J Knee Surg. 2003;16:21–26. - PubMed
-
- Bonnevialle P, Abid A, Mansat P, Verhaeghe L, Clément D, Mansat M. Ostéotomie tibiale de valgisation par addition médiale d’un coin de phosphate tricalcique. Rev Chir Orthop. 2002;88:486–492. - PubMed
-
- Bove JC. Utilisation d’une cale en céramique d’alumine poreuse dans l’ostéotomie tibiale de valgisation par ouverture interne. Rev Chir Orthop. 2002;88:480–485. - PubMed
-
- Coventry MB. Osteotomy of the upper portion of the tibia for degenerative arthritis of the knee. A preliminary report. J Bone Joint Surg Am. 1965;47:984–990. - PubMed
MeSH terms
LinkOut - more resources
Full Text Sources