Voltammetric determination of cefixime in pharmaceuticals and biological fluids
- PMID: 20678464
- DOI: 10.1016/j.ab.2010.07.027
Voltammetric determination of cefixime in pharmaceuticals and biological fluids
Abstract
Electroreduction and adsorption of cefixime was studied in phosphate buffer by cyclic voltammetry (CV), differential pulse cathodic adsorptive stripping voltammetry (DPCAdSV), and square-wave cathodic adsorptive stripping voltammetry (SWCAdSV) at hanging mercury drop electrode (HMDE). These fully validated sensitive and reproducible cathodic adsorptive stripping voltammetric procedures were applied for the trace determination of the bulk drug in pharmaceutical formulations and in human urine. The optimal experimental parameters were as follows: accumulation potential=-0.1 V (vs. Ag/AgCl, 3M KCl), accumulation time=50s, frequency=140 Hz, pulse amplitude=0.07 V, and scan increment=10 mV in phosphate buffer (pH 2.6). The first peak current showed a linear dependence with the drug concentration over the range of 50 ng ml(-1) to 25.6 μg ml(-1). The achieved limit of detection and limit of quantitation were 3.99 and 13.3 ng ml(-1) by SWCAdSV and 7.98 and 26.6 ng ml(-1) by DPCAdSV, respectively. The procedure was applied to assay the drug in tablets. Applicability was also tested in urine samples. Peak current was linear with the drug concentration in the range of 1 to 60 μg ml(-1) of the urine, and minimum detectability was found to be 12.6 ng ml(-1) by SWCAdSV and 58.4 ng ml(-1) by DPCAdSV.
Copyright © 2010 Elsevier Inc. All rights reserved.
Similar articles
-
Assay of the anti-psychotic drug haloperidol in bulk form, pharmaceutical formulation and biological fluids using square-wave adsorptive stripping voltammetry at a mercury electrode.J Pharm Biomed Anal. 2005 Jul 1;38(3):543-50. doi: 10.1016/j.jpba.2005.01.017. Epub 2005 Feb 26. J Pharm Biomed Anal. 2005. PMID: 15925258
-
Cathodic adsorptive stripping voltammetry of drotaverine hydrochloride and its determination in tablets and human urine by differential pulse voltammetry.Bioelectrochemistry. 2009 Apr;75(1):9-12. doi: 10.1016/j.bioelechem.2008.11.008. Epub 2008 Dec 6. Bioelectrochemistry. 2009. PMID: 19138886
-
Adsorptive stripping voltammetric behavior and determination of anticholinergic agent oxybutynin chloride on a mercury electrode.J Colloid Interface Sci. 2007 Oct 15;314(2):572-7. doi: 10.1016/j.jcis.2007.06.007. Epub 2007 Jul 5. J Colloid Interface Sci. 2007. PMID: 17618643
-
From mercury to nanosensors: Past, present and the future perspective of electrochemistry in pharmaceutical and biomedical analysis.J Pharm Biomed Anal. 2016 Oct 25;130:126-140. doi: 10.1016/j.jpba.2016.05.006. Epub 2016 May 6. J Pharm Biomed Anal. 2016. PMID: 27210510 Review.
-
Application of adsorptive stripping voltammetry for determination of selected methoxyimino cephalosporins in urine samples.Comb Chem High Throughput Screen. 2010 Sep;13(8):758-63. doi: 10.2174/138620710791920310. Comb Chem High Throughput Screen. 2010. PMID: 20426735 Review.
Cited by
-
Quantitative analysis of cefixime via complexation with palladium(II) in pharmaceutical formulations by spectrophotometry.J Pharm Anal. 2013 Aug;3(4):248-256. doi: 10.1016/j.jpha.2012.12.009. Epub 2013 Jan 14. J Pharm Anal. 2013. PMID: 29403825 Free PMC article.
-
Bi2O3/ZnO nanocomposite: Synthesis, characterizations and its application in electrochemical detection of balofloxacin as an anti-biotic drug.J Pharm Anal. 2021 Feb;11(1):57-67. doi: 10.1016/j.jpha.2020.03.013. Epub 2020 Apr 4. J Pharm Anal. 2021. PMID: 33717612 Free PMC article.
-
Cathodic adsorptive stripping voltammetry of an anti-emetic agent Granisetron in pharmaceutical formulation and biological matrix.J Pharm Anal. 2012 Dec;2(6):443-449. doi: 10.1016/j.jpha.2012.03.005. Epub 2012 Mar 18. J Pharm Anal. 2012. PMID: 29403780 Free PMC article.
-
Fabrication of novel TiO2 nanoparticles/Mn(III) salen doped carbon paste electrode: application as electrochemical sensor for the determination of hydrazine in the presence of phenol.Environ Monit Assess. 2015 Jul;187(7):407. doi: 10.1007/s10661-015-4629-9. Epub 2015 Jun 5. Environ Monit Assess. 2015. PMID: 26045039
-
Voltammetric sensor for tartrazine determination in soft drinks using poly (p-aminobenzenesulfonic acid)/zinc oxide nanoparticles in carbon paste electrode.J Food Drug Anal. 2017 Apr;25(2):293-301. doi: 10.1016/j.jfda.2016.10.002. Epub 2016 Nov 8. J Food Drug Anal. 2017. PMID: 28911670 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical