Acetabular orientation variability and symmetry based on CT scans of adults
- PMID: 20680495
- DOI: 10.1007/s11548-010-0521-9
Acetabular orientation variability and symmetry based on CT scans of adults
Abstract
Purpose: Understanding acetabular orientation is important in many orthopaedic procedures. Acetabular orientation, usually described by anteversion and abduction angles, has uncertain measurement variability in adult patients. The goals of this study are threefold: (1) to describe a new method for computing patient-specific abduction/anteversion angles from a single CT study based on the identification of anatomical landmarks and acetabular rim points; (2) to quantify the inaccuracies associated with landmark selection in computing the acetabular angles; and (3) to quantify the variability and symmetry of acetabular orientation.
Methods: A total of 25 CT studies from adult patients scanned for non-orthopaedic indications were retrospectively reviewed. The patients were randomly selected from the hospital's database. Inclusion criteria were adults 20-65 years of age. Acetabular landmark coordinates were identified by expert observers and tabulated in a spreadsheet. Two sets of calculations were done using the data: (1) computation of the abduction and anteversion for each patient, and (2) evaluation of the variability of measurements in the same individual by the same surgeon. The results were tabulated and summary statistics computed.
Results: This retrospective study showed that acetabular abduction and anteversion angles averaged 54 degrees and 17 degrees, respectively, in adults. A clinically significant intra-patient variability of >20 degrees was found. We also found that the right and left side rim plane orientation were significantly correlated, but were not always symmetric.
Conclusion: A new method of computing patient-specific abduction and anteversion angles from a CT study of the anterior pelvic plane and the left and right acetabular rim planes was reliable and accurate. We found that the acetabular rim plane can be reliably and accurately computed from identified points on the rim. The novelty of this work is that angular measurements are performed between planes on a 3-D model rather than lines on 2-D projections, as was done in the past.
Similar articles
-
Normative 3D acetabular orientation measurements by the low-dose EOS imaging system in 102 asymptomatic subjects in standing position: Analyses by side, gender, pelvic incidence and reproducibility.Orthop Traumatol Surg Res. 2017 Apr;103(2):209-215. doi: 10.1016/j.otsr.2016.11.010. Epub 2016 Dec 24. Orthop Traumatol Surg Res. 2017. PMID: 28025151
-
A cadaver study validating CT assessment of acetabular component orientation: the Perth CT hip protocol.Skeletal Radiol. 2017 Feb;46(2):177-183. doi: 10.1007/s00256-016-2527-z. Epub 2016 Nov 8. Skeletal Radiol. 2017. PMID: 27826701
-
Isolated acetabular revision with femoral stem retention using computed tomography-based navigation.Orthop Traumatol Surg Res. 2019 Nov;105(7):1311-1317. doi: 10.1016/j.otsr.2019.08.002. Epub 2019 Sep 12. Orthop Traumatol Surg Res. 2019. PMID: 31522901
-
Non-equivalent Results from Different Anteversion Measurements Methods for the Evaluation of the Acetabular Cup Orientation in Total Hip Arthroplasty.Orthop Surg. 2019 Apr;11(2):241-247. doi: 10.1111/os.12445. Epub 2019 Apr 1. Orthop Surg. 2019. PMID: 30932341 Free PMC article.
-
Imaging and navigation measurement of acetabular component position in THA.Clin Orthop Relat Res. 2009 Jan;467(1):32-42. doi: 10.1007/s11999-008-0597-5. Epub 2008 Nov 1. Clin Orthop Relat Res. 2009. PMID: 18979147 Free PMC article. Review.
Cited by
-
CT validation of intraoperative imageless navigation (Naviswiss) for component positioning accuracy in primary total hip arthroplasty in supine patient position: a prospective observational cohort study in a single-surgeon practice.Arthroplasty. 2023 Dec 5;5(1):63. doi: 10.1186/s42836-023-00217-z. Arthroplasty. 2023. PMID: 38049889 Free PMC article.
-
A Novel Approach of Customized Pelvic Implant Design Based on Symmetrical Analysis and 3D Printing.3D Print Addit Manuf. 2023 Oct 1;10(5):984-991. doi: 10.1089/3dp.2021.0121. Epub 2023 Oct 10. 3D Print Addit Manuf. 2023. PMID: 37886407 Free PMC article.
-
Acetabular Morphology and Spinopelvic Characteristics: What Predominantly Determines Functional Acetabular Version?Orthop J Sports Med. 2021 Oct 22;9(10):23259671211030495. doi: 10.1177/23259671211030495. eCollection 2021 Oct. Orthop J Sports Med. 2021. PMID: 34708135 Free PMC article.
-
Acetabular orientation: anatomical and functional measurement.Int J Comput Assist Radiol Surg. 2012 Mar;7(2):233-40. doi: 10.1007/s11548-011-0648-3. Epub 2011 Aug 7. Int J Comput Assist Radiol Surg. 2012. PMID: 21822915
-
Well-Placed Acetabular Component Oriented Outside the Safe Zone During Weight-Bearing Daily Activities.Front Bioeng Biotechnol. 2021 Jun 10;9:664907. doi: 10.3389/fbioe.2021.664907. eCollection 2021. Front Bioeng Biotechnol. 2021. PMID: 34178961 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous