Atrial pacing or ventricular backup-only pacing in implantable cardioverter-defibrillator patients
- PMID: 20685401
- DOI: 10.1016/j.hrthm.2010.05.038
Atrial pacing or ventricular backup-only pacing in implantable cardioverter-defibrillator patients
Abstract
Background: The need for pacing support in typical ICD patients is unknown.
Objective: This study sought to determine whether atrial pacing with ventricular backup pacing is equivalent to ventricular backup pacing only in implantable cardioverter-defibrillator (ICD) patients.
Methods: We randomized 1,030 patients from 84 sites with indications for ICDs, with sinus rhythm, and without symptomatic bradycardia to atrial pacing with ventricular backup at 60 beats/min (518) or ventricular backup pacing at 40 beats/min (512). The primary end points were time to death, heart failure hospitalization (HFH), and heart failure-related urgent care (HFUC).
Results: Follow-up was 2.4 ± 0.8 years when the trial was stopped for futility. There were 355 end point events (103 deaths, 252 HFH/HFUC) in 194 patients favoring ventricular backup pacing (event-free rate 77.7% vs. 80.3% for atrial pacing at 30 months; hazard ratio 1.14, upper confidence bound 1.59, prespecified noninferiority threshold 1.21), therefore equivalence between pacing arms was not demonstrated. Overall HFH/HFUC rates were slightly higher during atrial pacing (event-free rate 85.4% vs. 86.4% for ventricular backup pacing). Exploratory analyses revealed that the difference in HFH/HFUC rates was largely seen in patients with a PR interval ≥230 ms. There were no differences between groups for atrial fibrillation, ventricular tachycardia/ventricular fibrillation, quality of life, or echocardiographic measurements. Fewer patients in the atrial pacing group were reported to develop an indication for bradycardia pacing (3.7% vs. 7.3%, P = .0053).
Conclusion: Equivalence between atrial pacing and ventricular backup pacing only could not be demonstrated.
Clinical trials identifier: NCT00281099.
Copyright © 2010 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Similar articles
-
The DAVID (Dual Chamber and VVI Implantable Defibrillator) II trial.J Am Coll Cardiol. 2009 Mar 10;53(10):872-80. doi: 10.1016/j.jacc.2008.10.057. J Am Coll Cardiol. 2009. PMID: 19264245 Clinical Trial.
-
The Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial: rationale, design, results, clinical implications and lessons for future trials.Card Electrophysiol Rev. 2003 Dec;7(4):468-72. doi: 10.1023/B:CEPR.0000023165.20987.b1. Card Electrophysiol Rev. 2003. PMID: 15071277 Clinical Trial.
-
Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: the Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial.JAMA. 2002 Dec 25;288(24):3115-23. doi: 10.1001/jama.288.24.3115. JAMA. 2002. PMID: 12495391 Clinical Trial.
-
Role of permanent pacing to prevent atrial fibrillation: science advisory from the American Heart Association Council on Clinical Cardiology (Subcommittee on Electrocardiography and Arrhythmias) and the Quality of Care and Outcomes Research Interdisciplinary Working Group, in collaboration with the Heart Rhythm Society.Circulation. 2005 Jan 18;111(2):240-3. doi: 10.1161/01.CIR.0000151800.84945.47. Circulation. 2005. PMID: 15657388 Review.
-
The current status of the implantable cardioverter defibrillator.Annu Rev Med. 1996;47:85-93. doi: 10.1146/annurev.med.47.1.85. Annu Rev Med. 1996. PMID: 8712805 Review.
Cited by
-
The importance of avoiding unnecessary right ventricular pacing in clinical practice.World J Cardiol. 2013 Nov 26;5(11):410-9. doi: 10.4330/wjc.v5.i11.410. World J Cardiol. 2013. PMID: 24340139 Free PMC article. Review.
-
2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing.J Arrhythm. 2016 Feb;32(1):1-28. doi: 10.1016/j.joa.2015.12.001. Epub 2016 Feb 1. J Arrhythm. 2016. PMID: 26949427 Free PMC article. No abstract available.
-
Cardiomyopathy Associated with Right Ventricular Apical Pacing-Systematic Review and Meta-Analysis.J Clin Med. 2022 Nov 22;11(23):6889. doi: 10.3390/jcm11236889. J Clin Med. 2022. PMID: 36498462 Free PMC article. Review.
-
Avoiding unnecessary ventricular pacing is associated with reduced incidence of heart failure hospitalizations and persistent atrial fibrillation in pacemaker patients.Europace. 2023 May 19;25(5):euad065. doi: 10.1093/europace/euad065. Europace. 2023. PMID: 36942949 Free PMC article.
-
Association of single- vs dual-chamber ICDs with mortality, readmissions, and complications among patients receiving an ICD for primary prevention.JAMA. 2013 May 15;309(19):2025-34. doi: 10.1001/jama.2013.4982. JAMA. 2013. PMID: 23677314 Free PMC article.