Diagnostic value of finger systolic blood pressure in the assessment of vasospastic reactions in the finger skin of vibration-exposed subjects after finger and body cooling
- PMID: 2068557
- DOI: 10.5271/sjweh.1712
Diagnostic value of finger systolic blood pressure in the assessment of vasospastic reactions in the finger skin of vibration-exposed subjects after finger and body cooling
Abstract
To assess the severity of vibration-induced white finger (VWF), finger systolic blood pressure (FSBP) after finger cooling and after combined finger and body cooling was measured by strain-guage plethysmography for 100 vibration-exposed men and 22 healthy men. The exposed men were classified as being without VWF (EW), with mild VWF (EM), and with severe VWF (ES) according to records of blanching attacks. FSBP was significantly reduced only in the ES group after finger cooling and in the ES and EM groups after both body and finger cooling. The diagnostic sensitivity and specificity for VWF was 81.7 and 90.3%, respectively. Skin temperature measurements before and after immersion in cold water (5 degrees C, for 10 min) could not be used for the estimation of VWF severity.
Similar articles
-
Finger systolic blood pressure indices for the diagnosis of vibration-induced white finger.Int Arch Occup Environ Health. 2002 Jan;75(1-2):20-8. doi: 10.1007/s004200100274. Int Arch Occup Environ Health. 2002. PMID: 11898873
-
Finger peripheral resistance during local cold provocation in vasospastic disease.Scand J Work Environ Health. 1986 Aug;12(4 Spec No):395-9. doi: 10.5271/sjweh.2123. Scand J Work Environ Health. 1986. PMID: 3775329
-
Finger systolic blood pressure measurements after finger cooling. Using the laser-Doppler method for assessing vibration-induced white finger.J Occup Med. 1992 Jul;34(7):683-6. J Occup Med. 1992. PMID: 1494959
-
Diagnostic aspects of vibration-induced white finger.Int Arch Occup Environ Health. 2002 Jan;75(1-2):6-13. doi: 10.1007/s004200100272. Int Arch Occup Environ Health. 2002. PMID: 11898878 Review.
-
Finger thermometry in the assessment of subjects with vibration-induced white finger.Scand J Work Environ Health. 1987 Aug;13(4):348-51. doi: 10.5271/sjweh.2044. Scand J Work Environ Health. 1987. PMID: 3324314 Review.
Cited by
-
Technetium-99m hand perfusion scintigraphy (Raynaud's scan) as a method of verification in hand arm vibration syndrome: a review.Ann Occup Environ Med. 2022 Oct 11;34:e26. doi: 10.35371/aoem.2022.34.e26. eCollection 2022. Ann Occup Environ Med. 2022. PMID: 36452251 Free PMC article. Review.
-
Test battery for assessing vascular disturbances of fingers.Environ Health Prev Med. 2005 Nov;10(6):341-50. doi: 10.1007/BF02898195. Environ Health Prev Med. 2005. PMID: 21432118 Free PMC article.
-
Factors influencing finger systolic blood pressure test for diagnosis of vibration-induced white finger.Environ Health Prev Med. 2005 Nov;10(6):366-70. doi: 10.1007/BF02898198. Environ Health Prev Med. 2005. PMID: 21432121 Free PMC article.
-
Multicenter study on finger systolic blood pressure test for diagnosis of vibration-induced white finger.Int Arch Occup Environ Health. 2008 Apr;81(5):639-44. doi: 10.1007/s00420-007-0273-1. Epub 2007 Oct 25. Int Arch Occup Environ Health. 2008. PMID: 17960415
-
Standardization of finger systolic blood pressure (FSBP) cooling tests.Environ Health Prev Med. 2005 Nov;10(6):360-5. doi: 10.1007/BF02898197. Environ Health Prev Med. 2005. PMID: 21432120 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous