Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 Aug;138(2):208-14.
doi: 10.1016/j.ajodo.2008.09.034.

Effect of early orthodontic force on shear bond strength of orthodontic brackets bonded with different adhesive systems

Affiliations
Comparative Study

Effect of early orthodontic force on shear bond strength of orthodontic brackets bonded with different adhesive systems

Yasser Lotfy Abdelnaby et al. Am J Orthod Dentofacial Orthop. 2010 Aug.

Abstract

Introduction: This study was conducted to evaluate the effect of applying early orthodontic force on the shear bond strength (SBS) of orthodontic brackets bonded with 4 adhesive systems.

Methods: Eighty stainless steel brackets were bonded to the enamel surfaces of extracted premolars with 4 adhesive systems. For each adhesive, 10 brackets were bonded without application of force (groups 1, 3, 5, and 7), and another 10 were subjected to a 120-g force with a coil spring (groups 2, 4, 6, and 8). This force was applied 30 minutes after bonding and maintained for 24 hours. Groups 1 and 2 had Rely-a-bond primer and Rely-a-bond adhesive (Reliance Orthodontic Products, Itasca, Ill). Groups 3 and 4 had Transbond XT primer and Transbond XT adhesive (3M Unitek, Monrovia, Calif). Groups 5 and 6 had Transbond Plus Self Etching Primer and Transbond XT adhesive (3M Unitek). Groups 7 and 8 had RelyX Unicem (3M ESPE, Seefeld, Germany). After thermocycling, SBS testing was performed by using a universal testing machine (Type 500, Lloyd Instruments Ltd, Fareham Hants, UK). The results of SBS testing for all adhesives were analyzed by 2-way analysis of variance and the Duncan test. The unpaired Student t test was used to compare the effect of force on the SBS of each adhesive.

Results: Transbond XT primer and its adhesive had the highest values (without force, 11.2 +/- 3.1 MPa; with force, 10.7 +/- 2.7 MPa), and RelyX Unicem had the lowest (without force, 5.8 +/- 1.5MPa; with force, 5.7 +/- 1.6 MPa). Application of force yielded nonsignificant reductions in SBS for all adhesives; this reduction was less pronounced with RelyX Unicem.

Conclusions: For all studied adhesive systems, orthodontic force up to 120 g can be applied within the first hour after bonding with no deleterious effects on bond strength.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources