Should unstable extra-articular distal radial fractures be treated with fixed-angle volar-locked plates or percutaneous Kirschner wires? A prospective randomised controlled trial
- PMID: 20691441
- DOI: 10.1016/j.injury.2010.07.236
Should unstable extra-articular distal radial fractures be treated with fixed-angle volar-locked plates or percutaneous Kirschner wires? A prospective randomised controlled trial
Abstract
Fractures of the distal radius are commonly treated with cast immobilisation; however, those potentially unstable injuries with dorsal comminution may need operative intervention. This intervention is usually with manipulation and Kirschner wires but advances in locking-plate technology have enabled surgeons to achieve anatomical reconstruction of complex fracture patterns, even in poor-quality osteoporotic bone.To ascertain if fixed-angle volar-locked plates confer a significant benefit over manipulation and Kirschner-wire stabilisation, we prospectively randomised 56 adult patients with isolated, closed,unilateral, unstable extra-articular fractures into two treatment groups, one fixed with K-wires and the other fixed with a volar locking plate.Functional outcomes were assessed using Gartland and Werley and Disabilities of the Arm, Shoulder and Hand (DASH) scores. These were statistically better in the plate group at 3 and 6 months.Radiological assessment showed statistically better results at 6 weeks, 3 months and 6 months, postoperatively.In the plate group, there was no significant loss of fracture reduction.
2010 Elsevier Ltd. All rights reserved.
Comment in
-
Methodological issues of: should unstable extra-articular distal radial fractures be treated with fixed-angle volar-locked plates or percutaneous Kirschner wires? A prospective randomised controlled trial.Injury. 2012 Jul;43(7):1219; author reply 1222. doi: 10.1016/j.injury.2011.02.009. Epub 2011 Mar 5. Injury. 2012. PMID: 21377675 No abstract available.
Similar articles
-
Volar locking plates versus Kirschner wires for distal radial fractures--a cost analysis study.Injury. 2009 Dec;40(12):1279-81. doi: 10.1016/j.injury.2009.02.018. Epub 2009 Jun 13. Injury. 2009. PMID: 19524910
-
Are Volar Locking Plates Superior to Percutaneous K-wires for Distal Radius Fractures? A Meta-analysis.Clin Orthop Relat Res. 2015 Sep;473(9):3017-27. doi: 10.1007/s11999-015-4347-1. Epub 2015 May 16. Clin Orthop Relat Res. 2015. PMID: 25981715 Free PMC article. Review.
-
Comparative study between volar locked plates versus closed reduction with percutaneous pinning in management of unstable extra-articular distal radius fractures.J Pak Med Assoc. 2021 Dec;71(Suppl 8)(12):S35-S39. J Pak Med Assoc. 2021. PMID: 35130215
-
Dorsally displaced extra-articular distal radius fractures fixation: Dorsal IM nailing versus volar plating. A randomized controlled trial.Orthop Traumatol Surg Res. 2011 Sep;97(5):471-8. doi: 10.1016/j.otsr.2010.11.011. Epub 2011 Jun 11. Orthop Traumatol Surg Res. 2011. PMID: 21659011 Clinical Trial.
-
Is percutaneous pinning an outdated technique for distal radius fractures?Injury. 2019 Jun;50 Suppl 1:S30-S35. doi: 10.1016/j.injury.2019.03.048. Epub 2019 Mar 31. Injury. 2019. PMID: 30954251 Review.
Cited by
-
Comparison between Volar Locking Plate and Kirschner Wire Fixation for Unstable Distal Radius Fracture: A Meta-Analysis of Randomized Controlled Trials.J Wrist Surg. 2023 Apr 14;13(5):469-480. doi: 10.1055/s-0043-1768235. eCollection 2024 Oct. J Wrist Surg. 2023. PMID: 39296653 Free PMC article.
-
Treatment of unstable extra-articular distal radius fractures using locked volar plating and percutaneous pinning without external fixation.Int J Burns Trauma. 2020 Aug 15;10(4):113-120. eCollection 2020. Int J Burns Trauma. 2020. PMID: 32934865 Free PMC article.
-
Early postoperative improvements in the QuickDASH score after distal radius fracture are related to the type of surgical treatment.Eur J Orthop Surg Traumatol. 2015 Jul;25(5):865-9. doi: 10.1007/s00590-015-1626-1. Epub 2015 Apr 18. Eur J Orthop Surg Traumatol. 2015. PMID: 25893608
-
Older Patient Preferences for Internal Fixation after a Distal Radius Fracture: A Qualitative Study from the Wrist and Radius Injury Surgical Trial.Plast Reconstr Surg. 2018 Jul;142(1):34e-41e. doi: 10.1097/PRS.0000000000004454. Plast Reconstr Surg. 2018. PMID: 29952895 Free PMC article.
-
Cost and Complications of Percutaneous Fixation of Hand Fractures in a Procedure Room Versus the Operating Room.Hand (N Y). 2018 Jul;13(4):428-434. doi: 10.1177/1558944717715105. Epub 2017 Jun 29. Hand (N Y). 2018. PMID: 28660786 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous