S Harder et al. J Dent. 2010 Nov.

Abstract

Aim: The main goal of this prospective clinical study was to evaluate the outcome of inlay-retained fixed dental prostheses (FDPs) made from heat-pressed lithium-disilicate glass-ceramic.

Methods: Forty-five FDPs were placed in 42 patients (21 women, mean age 36.1 years and 21 men, mean age 42.0 years). The FDPs replaced 4 premolars and 19 molars in the maxilla and 4 premolars and 18 molars in the mandible. Preparations were performed in accordance with general principles for ceramic inlay restorations. Five of the 45 FDPs were hybrid-retained restorations, i.e. one abutment tooth with an inlay retainer and one with a full crown retainer. All FDPs were pressed in one piece using lithium-disilicate ceramic (IPS e.max Press, Ivoclar Vivadent). The minimum dimensions for the proximal connector were 4mm in height and 4mm in width (16 mm(2)) with a minimum occlusal ceramic thickness of 1.5mm. The surfaces of the inlay retainer were conditioned by etching with hydrofluoric acid 5% and silane application. Standard adhesive luting techniques were performed using a dentin adhesive (Syntac Classic, Ivoclar Vivadent) and a resin composite (Variolink II, Ivoclar Vivadent). Clinical follow-up examinations were performed annually.

Results: The mean observation periods were 70 months (minimum 4, maximum 123 months). Twenty-seven FDPs (60%) failed during the observation period and had to be replaced. The Kaplan-Meier survival rate for inlay-retained FDPs was 57% after 5 years and 38% after 8 years, while for hybrid-retained FDPs it was 100% after 5 and 60% after 8 years.

Conclusions: Inlay-retained FDPs made from lithium-disilicate ceramic present a high clinical failure rate and therefore cannot be recommended.