Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Sep;23(4):263-73.
doi: 10.1007/s10334-010-0225-8. Epub 2010 Aug 6.

Combining prospective motion correction and distortion correction for EPI: towards a comprehensive correction of motion and susceptibility-induced artifacts

Affiliations

Combining prospective motion correction and distortion correction for EPI: towards a comprehensive correction of motion and susceptibility-induced artifacts

Rainer Boegle et al. MAGMA. 2010 Sep.

Abstract

Object: State-of-the-art MR techniques that rely on echo planar imaging (EPI), such as real-time fMRI, are limited in their applicability by both subject motion and B(0) field inhomogeneities. The goal of this work is to demonstrate that in principle it is possible to accurately predict the B(0) field inhomogeneities that occur during echo planar imaging in the presence of large scale head motion and apply this knowledge for distortion correction.

Materials and methods: In this work, prospective motion correction is combined with a field-prediction method and a method for correcting geometric distortions in EPI. To validate the methods, echo planar images were acquired of a custom-made phantom rotated to different angles relative to the B(0) field. For each orientation, field maps were acquired for comparison with the field predictions.

Results: The calculated field maps are very similar to the measured field maps for all orientations used in the experiments. The root mean squared error (RMSE) of the difference maps was between 15 to 20 Hz. The quality of distortion correction using calculated field maps is comparable to distortion correction done with measured field maps.

Conclusion: The results suggest that distortion-free echo planar imaging of moving objects may be feasible if prospective motion correction is combined with a field inhomogeneity estimation approach.

PubMed Disclaimer

References

    1. Magn Reson Med. 1995 Jul;34(1):65-73 - PubMed
    1. Magn Reson Imaging. 2004 Apr;22(3):315-28 - PubMed
    1. Magn Reson Med. 2004 Sep;52(3):471-7 - PubMed
    1. Neuroimage. 2006 Jul 1;31(3):1038-50 - PubMed
    1. MAGMA. 2006 May;19(2):55-61 - PubMed

Publication types

LinkOut - more resources