Reversed-phase, high-pressure liquid chromatography of peptides and proteins with ion-pairing reagents
- PMID: 206966
- DOI: 10.1126/science.206966
Reversed-phase, high-pressure liquid chromatography of peptides and proteins with ion-pairing reagents
Abstract
Reversed-phase, high-pressure liquid chromatography has been successfully applied to the analysis of peptides and proteins by the addition of hydrophilic (for example, phosphoric acid) or hydrophobic (for example, hexanesulfonic acid) ion-pairing reagents, or both, to the mobile phase. Examples described included proteins such as insulin, glucagon, and 1-24 ACTH pentaacetate (ACTH is adrenocorticotrophic hormone).
Similar articles
-
Application of reversed-phase HPLC in some critical peptide separations.J Chromatogr Sci. 1984 Jun;22(6):234-8. doi: 10.1093/chromsci/22.6.234. J Chromatogr Sci. 1984. PMID: 6086687
-
Separation of some polypeptide hormones by high-performance liquid chromatography.J Chromatogr. 1979 Apr 21;172:163-77. doi: 10.1016/s0021-9673(00)90954-3. J Chromatogr. 1979. PMID: 232884
-
Reversed-phase high-performance liquid chromatography of neuropeptides related to adrenocorticotropin, including a potent adrenocorticotropin 4-9 analogue (ORG 2766).J Chromatogr. 1982 Dec 10;233:317-23. doi: 10.1016/s0378-4347(00)81760-0. J Chromatogr. 1982. PMID: 6298261 No abstract available.
-
Micropreparative high-performance liquid chromatography of proteins and peptides.J Pharm Biomed Anal. 1989;7(9):1039-53. doi: 10.1016/0731-7085(89)80043-3. J Pharm Biomed Anal. 1989. PMID: 2490112 Review.
-
The effect of the mobile phase additives on sensitivity in the analysis of peptides and proteins by high-performance liquid chromatography-electrospray mass spectrometry.J Chromatogr B Analyt Technol Biomed Life Sci. 2005 Oct 25;825(2):111-23. doi: 10.1016/j.jchromb.2005.03.041. Epub 2005 Apr 26. J Chromatogr B Analyt Technol Biomed Life Sci. 2005. PMID: 16213445 Review.
Cited by
-
Optimization of reversed-phase peptide liquid chromatography ultraviolet mass spectrometry analyses using an automated blending methodology.J Biomol Tech. 2005 Dec;16(4):327-35. J Biomol Tech. 2005. PMID: 16522853 Free PMC article.
-
Reversed-phase fused-core HPLC modeling of peptides.J Pharm Anal. 2013 Apr;3(2):93-101. doi: 10.1016/j.jpha.2012.11.002. Epub 2012 Nov 30. J Pharm Anal. 2013. PMID: 29403802 Free PMC article.
-
Two forms of murine epidermal growth factor: rapid separation by using reverse-phase HPLC.Proc Natl Acad Sci U S A. 1982 Oct;79(19):5753-7. doi: 10.1073/pnas.79.19.5753. Proc Natl Acad Sci U S A. 1982. PMID: 6985267 Free PMC article.
-
Identification and quantification of glycoproteins using ion-pairing normal-phase liquid chromatography and mass spectrometry.Mol Cell Proteomics. 2009 Sep;8(9):2170-85. doi: 10.1074/mcp.M900088-MCP200. Epub 2009 Jun 12. Mol Cell Proteomics. 2009. PMID: 19525481 Free PMC article.
-
Prediction of peptide retention times in high-pressure liquid chromatography on the basis of amino acid composition.Proc Natl Acad Sci U S A. 1980 Mar;77(3):1632-6. doi: 10.1073/pnas.77.3.1632. Proc Natl Acad Sci U S A. 1980. PMID: 6929513 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources