Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 Aug;69(2):411-7.
doi: 10.1097/TA.0b013e3181ec9417.

Effects of hybrid plating with locked and nonlocked screws on the strength of locked plating constructs in the osteoporotic diaphysis

Affiliations
Comparative Study

Effects of hybrid plating with locked and nonlocked screws on the strength of locked plating constructs in the osteoporotic diaphysis

Josef Doornink et al. J Trauma. 2010 Aug.

Abstract

Background: Hybrid plating (HP) may improve fixation strength of locked plating (LP) constructs by combining the use of locked and nonlocked screws within a bone segment. This biomechanical study evaluated whether a hybrid bridge plating construct provides greater fixation strength than an all-locked construct in the osteoporotic diaphysis.

Methods: LP and HP constructs were applied to a validated surrogate of the osteoporotic femoral diaphysis in a bridge plating configuration. In LP constructs, plates were applied with three locking screws on each side of the fracture gap and remained 1 mm elevated. In HP constructs, plates were applied with two conventional screws complemented by a single locked screw on each side of the fracture. Constructs were tested under dynamic loading to failure in bending, torsion, and axial loading to analyze construct strength and failure mechanism in each loading mode.

Results: Compared with the LP construct, the HP construct was 7% stronger in bending (p = 0.17), 42% stronger in torsion (p < 0.001), and 7% weaker in axial compression (p = 0.003). In bending, constructs failed by periprosthetic fracture. In torsion, LP constructs failed by screw breakage, and HP constructs failed by periprosthetic fracture or breakage of the locking screw. In axial compression, all constructs failed by screw migration.

Conclusions: HP delivered similar bending strength and higher torsional strength than an all-locked bridge plating construct, while causing only a small decrease in axial strength. It may therefore provide an attractive alternative to an all-locked construct for plate fixation in the osteoporotic diaphysis.

PubMed Disclaimer

Publication types