Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Nov;31(8):1166-70.
doi: 10.1007/s00246-010-9776-8. Epub 2010 Aug 13.

Respiratory variation in aortic blood flow velocity as a predictor of fluid responsiveness in children after repair of ventricular septal defect

Affiliations

Respiratory variation in aortic blood flow velocity as a predictor of fluid responsiveness in children after repair of ventricular septal defect

Deok Young Choi et al. Pediatr Cardiol. 2010 Nov.

Abstract

This study aimed to compare respiratory variation in transthoracic echo-derived aortic blood flow velocity (∆Vpeak) and inferior vena cava diameter (∆IVCD) with central venous pressure (CVP) as predictors of fluid responsiveness in children after repair of ventricular septal defect (VSD). A prospective study conducted in pediatric intensive care unit investigated 21 mechanically ventilated children who had undergone repair of VSD. Standardized volume replacement (VR) was the intervention used. Hemodynamic measurements including CVP, heart rate, mean arterial pressure, transthoracic echo-derived stroke volume (SV), cardiac output, ∆Vpeak, and ∆IVCD were performed 1 h after patient arrival in the intensive care unit. Hemodynamic measurements were repeated 10 min after VR by an infusion of 6% hydroxyethyl starch 130/0.4 (10 ml/kg) over 20 min. The volume-induced increase in the SV was 15% or more in 11 patients (responders) and less than 15% in 10 patients (nonresponders). Before volume replacement, the ∆Vpeak (23.1 ± 5.7% vs. 14.0 ± 7.7%; p = 0.006) and ∆IVCD (26.5 ± 16.2% vs. 9.2 ± 9.1%; p = 0.008) was higher in the responders than in the nonresponders, whereas CVP did not significantly differ between the two groups. The prediction of fluid responsiveness was higher with the ΔVpeak, as shown by a receiver operating characteristic curve area of 0.83 (95% confidence interval [CI], 0.61-1.00; p = 0.01), a ΔIVCD of 0.85 (95% CI, 0.69-1.00; p = 0.01), and a CVP of 0.48 (95% CI, 0.22-0.73; nonsignificant difference). The ∆Vpeak and ∆IVCD measured by transthoracic echocardiography can predict the response of SV after volume expansion in mechanically ventilated children at completion of VSD repair.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Intensive Care Med. 2004 Sep;30(9):1834-7 - PubMed
    1. Intensive Care Med. 2008 May;34(5):888-94 - PubMed
    1. Intensive Care Med. 2003 Mar;29(3):476-80 - PubMed
    1. Chest. 2008 Jul;134(1):172-8 - PubMed
    1. Echocardiography. 2009 Feb;26(2):140-9 - PubMed

Publication types

MeSH terms

LinkOut - more resources