Heart monitoring garments using textile electrodes for healthcare applications
- PMID: 20703570
- DOI: 10.1007/s10916-009-9356-8
Heart monitoring garments using textile electrodes for healthcare applications
Abstract
We measured the electrical activity signals of the heart through vital signs monitoring garments that have textile electrodes in conductive yarns while the subject is in stable and dynamic motion conditions. To measure the electrical activity signals of the heart during daily activities, four types of monitoring garment were proposed. Two experiments were carried out as follows: the first experiment sought to discover which garment led to the least displacement of the textile electrode from its originally intended location on the wearer's body. In the second, we measured and compared the electrical activity signals of the heart between the wearer's stable and dynamic motion states. The results indicated that the most appropriate type of garment sensing-wise was the "cross-type", and it seems to stabilize the electrode's position more effectively. The value of SNR of ECG signals for the "cross-type" garment is the highest. Compared to the "chest-belt-type" garment, which has already been marketed commercially, the "cross-type" garment was more efficient and suitable for heart activity monitoring.
Similar articles
-
A Study on the Optimal Positions of ECG Electrodes in a Garment for the Design of ECG-Monitoring Clothing for Male.J Med Syst. 2015 Sep;39(9):95. doi: 10.1007/s10916-015-0279-2. Epub 2015 Aug 8. J Med Syst. 2015. PMID: 26254250
-
Design of a smart ECG garment based on conductive textile electrode and flexible printed circuit board.Technol Health Care. 2017 Aug 9;25(4):815-821. doi: 10.3233/THC-170828. Technol Health Care. 2017. PMID: 28436408
-
Electrode placement in electrocardiography smart garments: A review.J Electrocardiol. 2019 Nov-Dec;57:27-30. doi: 10.1016/j.jelectrocard.2019.08.015. Epub 2019 Aug 21. J Electrocardiol. 2019. PMID: 31473476 Review.
-
Assessment of signal quality measured with a smart 12-lead ECG acquisition T-shirt.Ann Noninvasive Electrocardiol. 2020 Jan;25(1):e12682. doi: 10.1111/anec.12682. Epub 2019 Jul 24. Ann Noninvasive Electrocardiol. 2020. PMID: 31339208 Free PMC article.
-
Wearable Smart Textiles for Long-Term Electrocardiography Monitoring-A Review.Sensors (Basel). 2021 Jun 17;21(12):4174. doi: 10.3390/s21124174. Sensors (Basel). 2021. PMID: 34204577 Free PMC article. Review.
Cited by
-
Sensorized T-Shirt with Intarsia-Knitted Conductive Textile Integrated Interconnections: Performance Assessment of Cardiac Measurements during Daily Living Activities.Sensors (Basel). 2023 Nov 16;23(22):9208. doi: 10.3390/s23229208. Sensors (Basel). 2023. PMID: 38005593 Free PMC article.
-
A Study on the Optimal Positions of ECG Electrodes in a Garment for the Design of ECG-Monitoring Clothing for Male.J Med Syst. 2015 Sep;39(9):95. doi: 10.1007/s10916-015-0279-2. Epub 2015 Aug 8. J Med Syst. 2015. PMID: 26254250
-
Design and implementation of a BSN-based system for plantar health evaluation with exercise load quantification.Biomed Eng Online. 2017 Aug 3;16(1):98. doi: 10.1186/s12938-017-0389-9. Biomed Eng Online. 2017. PMID: 28774311 Free PMC article.
-
The effect of textile-based inductive coil sensor positions for heart rate monitoring.J Med Syst. 2014 Feb;38(2):2. doi: 10.1007/s10916-013-0002-0. Epub 2014 Jan 31. J Med Syst. 2014. PMID: 24481717
-
Nanomaterials-patterned flexible electrodes for wearable health monitoring: a review.J Mater Sci. 2021;56(27):14900-14942. doi: 10.1007/s10853-021-06248-8. Epub 2021 Jun 28. J Mater Sci. 2021. PMID: 34219807 Free PMC article. Review.