The advantages of wearable green reflected photoplethysmography

Affiliations
Comparative Study

The advantages of wearable green reflected photoplethysmography

Yuka Maeda et al. J Med Syst. 2011 Oct.

Abstract

This report evaluates the efficacy of reflected-type green light photoplethysmography (green light PPG). Transmitted infrared light was used for PPG and the arterial pulse was monitored transcutaneously. The reflected PPG signal contains AC components based on the heartbeat-related signal from the arterial blood flow and DC components, which include reflectance and scattering from tissue. Generally, changes in AC components are monitored, but the DC components play an important role during heat stress. In this study, we compared the signal of green light PPG to infrared PPG and ECG during heat stress. The wavelengths of the green and infrared light were 525 nm and 880 nm, respectively. Experiments were performed on young healthy subjects in cold (10°C), hot (45°C), and normal environments. The pulse rates were compared among three measurement devices and the AC and DC components of the PPG signal were evaluated during heat stress. The pulse rates obtained from green light PPG were strongly correlated with the R-R interval of an electrocardiogram in all environments, but those obtained from infrared light PPG displayed a weaker correlation with cold exposure. The AC components were of similar signal output for both wavelengths during heat stress. Also, the DC components for green light PPG were similar during heat stress, but showed less signal output for infrared light PPG during hot exposure. The main reason for the reduced DC components was speculated to be the increased blood flow at the vascular bed. Therefore, reflected green light PPG can be useful for pulse rate monitoring because it is less influenced by the tissue and vein region.

PubMed Disclaimer

References

    1. Med Biol Eng Comput. 1984 May;22(3):212-5 - PubMed
    1. Arch Otolaryngol Head Neck Surg. 2000 May;126(5):659-62 - PubMed
    1. IEEE Eng Med Biol Mag. 2003 May-Jun;22(3):28-40 - PubMed
    1. Physiol Meas. 2007 Mar;28(3):R1-39 - PubMed
    1. J Invest Dermatol. 1981 Jul;77(1):13-9 - PubMed

Publication types

LinkOut - more resources