Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 Aug;24(4):207-12.
doi: 10.3341/kjo.2010.24.4.207. Epub 2010 Aug 3.

Long-term efficacy and rotational stability of AcrySof toric intraocular lens implantation in cataract surgery

Affiliations
Comparative Study

Long-term efficacy and rotational stability of AcrySof toric intraocular lens implantation in cataract surgery

Myung Hun Kim et al. Korean J Ophthalmol. 2010 Aug.

Abstract

Purpose: To evaluate the long-term efficacy and rotational stability of the AcrySof toric intraocular lens (IOL) in correcting preoperative astigmatism in cataract patients.

Methods: This prospective observational study included 30 eyes from 24 consecutive patients who underwent implantation of an AcrySof toric IOL with micro-coaxial cataract surgery between May 2008 and September 2008. Outcomes of visual acuity, refractive and keratometric astigmatism, and IOL rotation after 1 day, 1 month, 3 months, and long-term (mean, 13.3+/-5.0 months) follow-up were evaluated.

Results: At final follow-up, 73.3% of eyes showed an uncorrected visual acuity of 20/25 or better. The postoperative keratometric value was not different from the preoperative value; mean refractive astigmatism was reduced to -0.28+/-0.38 diopter (D) from -1.28+/-0.48 D. The mean rotation of the toric IOL was 3.45+/-3.39 degrees at final follow-up. One eye (3.3%) exhibited IOL rotation of 10.3 degrees, the remaining eyes (96.7%) had IOL rotation of less than 10 degrees.

Conclusions: Early postoperative and long-term follow-up showed that implantation of the AcrySof toric IOL is an effective, safe, and predictable method for managing corneal astigmatism in cataract patients.

Keywords: Astigmatism; Cataract surgery; Toric intraocular lens.

PubMed Disclaimer

Conflict of interest statement

No potential conflict of interest relevant to this article was reported.

Figures

Fig. 1
Fig. 1
Visual outcomes. Both postoperative uncorrected visual acuity (UCVA) and best spectacle-corrected visual acuity (BCVA) were significantly improved when compared with preoperative values (p<0.05) (mean final follow-up, 13.3±5.0 months). LogMAR=logarithm of the minimum angle of resolution.
Fig. 2
Fig. 2
Refractive outcome. Mean refractive cylinder significantly improved compared to preoperative values during all follow-up periods (mean final follow-up, 13.3±5.0 months). D=diopter.
Fig. 3
Fig. 3
Change in refractive cylinder. D=diopter.
Fig. 4
Fig. 4
Rotation of toric intraocular lenses at final follow-up.
Fig. 5
Fig. 5
Mean absolute rotation of the toric intraocular lens over time (mean final follow-up, 13.3±5.0 months).

Similar articles

Cited by

References

    1. Hoffer KJ. Biometry of 7,500 cataractous eyes. Am J Ophthalmol. 1980;90:360–368. - PubMed
    1. Shimizu K, Misawa A, Suzuki Y. Toric intraocular lenses: correcting astigmatism while controlling axis shift. J Cataract Refract Surg. 1994;20:523–526. - PubMed
    1. Grabow HB. Early results of 500 cases of no-stitch cataract surgery. J Cataract Refract Surg. 1991;17(Suppl):726–730. - PubMed
    1. Werblin TP. Do three-piece PMMA IOLs rotate after implantation in the capsular bag? J Refract Surg. 1995;11:468–471. - PubMed
    1. Ruhswurm I, Scholz U, Zehetmayer M, et al. Astigmatism correction with a foldable toric intraocular lens in cataract patients. J Cataract Refract Surg. 2000;26:1022–1027. - PubMed

Publication types

MeSH terms