Long-term efficacy and rotational stability of AcrySof toric intraocular lens implantation in cataract surgery
- PMID: 20714383
- PMCID: PMC2916101
- DOI: 10.3341/kjo.2010.24.4.207
Long-term efficacy and rotational stability of AcrySof toric intraocular lens implantation in cataract surgery
Abstract
Purpose: To evaluate the long-term efficacy and rotational stability of the AcrySof toric intraocular lens (IOL) in correcting preoperative astigmatism in cataract patients.
Methods: This prospective observational study included 30 eyes from 24 consecutive patients who underwent implantation of an AcrySof toric IOL with micro-coaxial cataract surgery between May 2008 and September 2008. Outcomes of visual acuity, refractive and keratometric astigmatism, and IOL rotation after 1 day, 1 month, 3 months, and long-term (mean, 13.3+/-5.0 months) follow-up were evaluated.
Results: At final follow-up, 73.3% of eyes showed an uncorrected visual acuity of 20/25 or better. The postoperative keratometric value was not different from the preoperative value; mean refractive astigmatism was reduced to -0.28+/-0.38 diopter (D) from -1.28+/-0.48 D. The mean rotation of the toric IOL was 3.45+/-3.39 degrees at final follow-up. One eye (3.3%) exhibited IOL rotation of 10.3 degrees, the remaining eyes (96.7%) had IOL rotation of less than 10 degrees.
Conclusions: Early postoperative and long-term follow-up showed that implantation of the AcrySof toric IOL is an effective, safe, and predictable method for managing corneal astigmatism in cataract patients.
Keywords: Astigmatism; Cataract surgery; Toric intraocular lens.
Conflict of interest statement
No potential conflict of interest relevant to this article was reported.
Figures
References
-
- Hoffer KJ. Biometry of 7,500 cataractous eyes. Am J Ophthalmol. 1980;90:360–368. - PubMed
-
- Shimizu K, Misawa A, Suzuki Y. Toric intraocular lenses: correcting astigmatism while controlling axis shift. J Cataract Refract Surg. 1994;20:523–526. - PubMed
-
- Grabow HB. Early results of 500 cases of no-stitch cataract surgery. J Cataract Refract Surg. 1991;17(Suppl):726–730. - PubMed
-
- Werblin TP. Do three-piece PMMA IOLs rotate after implantation in the capsular bag? J Refract Surg. 1995;11:468–471. - PubMed
-
- Ruhswurm I, Scholz U, Zehetmayer M, et al. Astigmatism correction with a foldable toric intraocular lens in cataract patients. J Cataract Refract Surg. 2000;26:1022–1027. - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
