Hysteroscopic removal of intrauterine contraceptive device embedded within submucous myoma
- PMID: 20716271
- DOI: 10.1111/j.1479-828X.2010.01188.x
Hysteroscopic removal of intrauterine contraceptive device embedded within submucous myoma
Abstract
We report that an intrauterine contraceptive device (IUCD) embedded within intrauterine tumour (submucous myoma) in a postmenopausal woman was misdiagnosed, definitively diagnosed and successfully removed with hysteroscopic resection. Hysteroscopy and hysteroscopic resection of the submucous myoma with IUCD should be reserved as a minimally invasive, safe and reliable treatment method, and can avoid a laparotomy and hysterotomy. This is believed to be the first reported case of such an occurrence.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical