Noninvasive estimation of global activation sequence using the extended Kalman filter
- PMID: 20716498
- PMCID: PMC3235525
- DOI: 10.1109/TBME.2010.2066564
Noninvasive estimation of global activation sequence using the extended Kalman filter
Abstract
A new algorithm for 3-D imaging of the activation sequence from noninvasive body surface potentials is proposed. After formulating the nonlinear relationship between the 3-D activation sequence and the body surface recordings during activation, the extended Kalman filter (EKF) is utilized to estimate the activation sequence in a recursive way. The state vector containing the activation sequence is optimized during iteration by updating the error variance/covariance matrix. A new regularization scheme is incorporated into the "predict" procedure of EKF to tackle the ill-posedness of the inverse problem. The EKF-based algorithm shows good performance in simulation under single-site pacing. Between the estimated activation sequences and true values, the average correlation coefficient (CC) is 0.95, and the relative error (RE) is 0.13. The average localization error (LE) when localizing the pacing site is 3.0 mm. Good results are also obtained under dual-site pacing (CC = 0.93, RE = 0.16, and LE = 4.3 mm). Furthermore, the algorithm shows robustness to noise. The present promising results demonstrate that the proposed EKF-based inverse approach can noninvasively estimate the 3-D activation sequence with good accuracy and the new algorithm shows good features due to the application of EKF.
Figures




Similar articles
-
Three-dimensional activation sequence imaging in a rabbit model.Annu Int Conf IEEE Eng Med Biol Soc. 2007;2007:5609-11. doi: 10.1109/IEMBS.2007.4353618. Annu Int Conf IEEE Eng Med Biol Soc. 2007. PMID: 18003284
-
Noninvasive reconstruction of three-dimensional ventricular activation sequence from the inverse solution of distributed equivalent current density.IEEE Trans Med Imaging. 2006 Oct;25(10):1307-18. doi: 10.1109/tmi.2006.882140. IEEE Trans Med Imaging. 2006. PMID: 17024834
-
Three-dimensional cardiac electrical imaging from intracavity recordings.IEEE Trans Biomed Eng. 2007 Aug;54(8):1454-60. doi: 10.1109/TBME.2007.891932. IEEE Trans Biomed Eng. 2007. PMID: 17694866
-
Noninvasive three-dimensional activation time imaging of ventricular excitation by means of a heart-excitation model.Phys Med Biol. 2002 Nov 21;47(22):4063-78. doi: 10.1088/0031-9155/47/22/310. Phys Med Biol. 2002. PMID: 12476982
-
Tikhonov regularization-based extended Kalman filter technique for robust and accurate reconstruction in diffuse optical tomography.J Opt Soc Am A Opt Image Sci Vis. 2023 Jan 1;40(1):10-20. doi: 10.1364/JOSAA.476795. J Opt Soc Am A Opt Image Sci Vis. 2023. PMID: 36607070
Cited by
-
Noninvasive imaging of cardiac excitation: current status and future perspective.Ann Noninvasive Electrocardiol. 2014 Mar;19(2):105-13. doi: 10.1111/anec.12140. Epub 2014 Feb 19. Ann Noninvasive Electrocardiol. 2014. PMID: 24620843 Free PMC article. Review.
-
Closed-loop brain-machine-body interfaces for noninvasive rehabilitation of movement disorders.Ann Biomed Eng. 2014 Aug;42(8):1573-93. doi: 10.1007/s10439-014-1032-6. Epub 2014 May 15. Ann Biomed Eng. 2014. PMID: 24833254 Free PMC article. Review.
-
Temporal Sparse Promoting Three Dimensional Imaging of Cardiac Activation.IEEE Trans Med Imaging. 2015 Nov;34(11):2309-19. doi: 10.1109/TMI.2015.2429134. Epub 2015 May 4. IEEE Trans Med Imaging. 2015. PMID: 25955987 Free PMC article.
-
Noninvasive Imaging of Epicardial and Endocardial Potentials With Low Rank and Sparsity Constraints.IEEE Trans Biomed Eng. 2019 Sep;66(9):2651-2662. doi: 10.1109/TBME.2019.2894286. Epub 2019 Jan 21. IEEE Trans Biomed Eng. 2019. PMID: 30668450 Free PMC article.
-
ML and MAP estimation of parameters for the Kalman filter and smoother applied to electrocardiographic imaging.Med Biol Eng Comput. 2019 Oct;57(10):2093-2113. doi: 10.1007/s11517-019-02018-6. Epub 2019 Jul 30. Med Biol Eng Comput. 2019. PMID: 31363890
References
-
- Gepstein L, Hayam G, Ben-Haim SA. A novel method for nonfluoroscopic catheter-based electroanatomical mapping of the heart: in vitro and in vivo accuracy results. Circulation. 1997;95:1611–1622. - PubMed
-
- Gornick CC, Adler SW, Pederson B, Hauck J, Budd J, Schweitzer J. Validation of a new noncontact catheter system for electroanatomic mapping of left Ventricular Endocardium. Circulation. 1999;99:829–835. - PubMed
-
- Barr RC, Spach MS. Inverse calculation of QRS-T epicardial potentials from normal and ectopic beats in the dogm. Circ Res. 1978;42:661–675. - PubMed
-
- Oster HS, Rudy Y. The use of temporal information in the regularization of the inverse problem of electrocardiography. IEEE Trans Biomed Eng. 1992;39:65–75. - PubMed
-
- Shahidi AV, Savard P, Nadeau R. Forward and inverse problems of electrocardiography: modeling and recovery of epicardial potentials in humans. IEEE Trans Biomed Eng. 1994;41:249–256. - PubMed