Corneal imaging with slit-scanning and Scheimpflug imaging techniques
- PMID: 20718786
- DOI: 10.1111/j.1444-0938.2010.00509.x
Corneal imaging with slit-scanning and Scheimpflug imaging techniques
Abstract
Modern anterior segment imaging techniques, such as slit-scanning and Scheimpflug imaging, greatly improved the field of corneal imaging. Devices such as the Orbscan (Bausch & Lomb Surgical, Inc) and, more recently, the Pentacam (Oculus, Inc) and the Galilei (Ziemer Ophthalmic Systems AG) have brought a whole new range of clinical possibilities and sparked interest in the academic community. These new tomographers create three-dimensional models of the cornea and enable the direct measurement of both the anterior and posterior surface elevations. In this paper, we present a review of some available literature on those systems, regarding their optical principles and their performance in current clinical applications.
© 2010 The Authors. Clinical and Experimental Optometry © 2010 Optometrists Association Australia.
Similar articles
-
Central corneal thickness measurement with Pentacam, Orbscan II, and ultrasound devices before and after laser refractive surgery for myopia.J Cataract Refract Surg. 2007 Oct;33(10):1701-7. doi: 10.1016/j.jcrs.2007.05.040. J Cataract Refract Surg. 2007. PMID: 17889763
-
Repeatability, reproducibility, and agreement characteristics of rotating Scheimpflug photography and scanning-slit corneal topography for corneal power measurement.J Cataract Refract Surg. 2009 Jan;35(1):127-33. doi: 10.1016/j.jcrs.2008.10.019. J Cataract Refract Surg. 2009. PMID: 19101435
-
Comparison of posterior corneal imaging before and after LASIK using dual rotating scheimpflug and scanning slit-beam corneal tomography systems.J Refract Surg. 2013 Feb;29(2):96-101. doi: 10.3928/1081597X-20130117-03. J Refract Surg. 2013. PMID: 23380409
-
Corneal assessment technologies: current status.Surv Ophthalmol. 2014 Nov-Dec;59(6):599-614. doi: 10.1016/j.survophthal.2014.05.001. Epub 2014 May 24. Surv Ophthalmol. 2014. PMID: 25223496 Review.
-
[Corneal topography. Analysis of the corneal surface].Ophthalmologe. 2008 Feb;105(2):193-204; quiz 205-6. doi: 10.1007/s00347-008-1696-0. Ophthalmologe. 2008. PMID: 18265992 Review. German.
Cited by
-
The effect of corneal irregularity on astigmatism measurement by automated versus ray tracing keratometry.Medicine (Baltimore). 2015 Apr;94(13):e677. doi: 10.1097/MD.0000000000000677. Medicine (Baltimore). 2015. PMID: 25837759 Free PMC article.
-
Single session, intrauser repeatability of anterior chamber biometric and corneal pachy-volumetric parameters using a new Scheimpflug+Placido device.J Optom. 2016 Apr-Jun;9(2):85-92. doi: 10.1016/j.optom.2015.07.001. Epub 2015 Sep 1. J Optom. 2016. PMID: 26338543 Free PMC article.
-
Comparability and repeatability of pachymetry in keratoconus using four noncontact techniques.Indian J Ophthalmol. 2015 Sep;63(9):722-7. doi: 10.4103/0301-4738.170987. Indian J Ophthalmol. 2015. PMID: 26632128 Free PMC article.
-
Comparison of Toric Intraocular Lens Axis Accuracy between Optical Biometry and Dual Scheimpflug Topography.Korean J Ophthalmol. 2025 Feb;39(1):64-70. doi: 10.3341/kjo.2024.0117. Epub 2025 Jan 9. Korean J Ophthalmol. 2025. PMID: 39780041 Free PMC article.
-
The influence of routine uncomplicated phacoemulsification on the orthogonality of the cornea.Indian J Ophthalmol. 2021 May;69(5):1073-1079. doi: 10.4103/ijo.IJO_1168_20. Indian J Ophthalmol. 2021. PMID: 33913835 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources