Comparative Study
. 2011 Apr;27(4):579-86.
doi: 10.1007/s10554-010-9683-3. Epub 2010 Aug 19.

Use of 100 kV versus 120 kV in cardiac dual source computed tomography: effect on radiation dose and image quality

Affiliations
Comparative Study

Use of 100 kV versus 120 kV in cardiac dual source computed tomography: effect on radiation dose and image quality

Ron Blankstein et al. Int J Cardiovasc Imaging. 2011 Apr.

Abstract

To evaluate the effective radiation dose and image quality resulting from use of 100 vs. 120 kV among patients referred for cardiac dual source CT exam (DSCT). Prospective data was collected on 294 consecutive patients referred for DSCT. For each scan, a physician specializing in cardiac CT chose all parameters including tube current and voltage, axial versus helical acquisition, and use of tube current modulation. Lower tube voltage was selected for thinner patients or when lower radiation was desired for younger patients, particularly females. For each study, image quality (IQ) was rated on a subjective IQ score and contrast (CNR) and signal-to-noise (SNR) ratios were calculated. Tube voltage of 100 kV was used for 77 (26%) exams while 120 kV was used for 217 (74%) exams. Use of 100 kV was more common in thinner patients (weight 166 lbs vs. 199 lbs, P < .001). The effective radiation dose for the 100 and 120 kV scans was 8.5 and 15.4 mSv respectively. Among scans utilizing 100 and 120 kV, there was no difference in exam indication, use of beta blockers, heart rate, scan length and use of radiation saving techniques such as prospective ECG triggering and tube current modulation. The IQ score was significantly higher for 100 kV scans. While 100 kV scans were found to have higher image noise then those utilizing 120 kV, the contrast-to-noise and signal-to-noise were significantly higher (SNR: 9.4 vs. 8.3, P = .02; CNR: 6.9 vs. 6.0, P = .02). In selected non-obese patients, use of low kV results in a substantial reduction of radiation dose and may result in improved image quality. These results suggest that low kV should be used more frequently in non-obese patients.

PubMed Disclaimer

Comment in

  • 100 kV versus 120 kV: effective reduction in radiation dose?
    van der Wall EE, Jukema JW, Schuijf JD, Bax JJ. van der Wall EE, et al. Int J Cardiovasc Imaging. 2011 Apr;27(4):587-91. doi: 10.1007/s10554-010-9693-1. Epub 2010 Sep 1. Int J Cardiovasc Imaging. 2011. PMID: 20809283 Free PMC article. No abstract available.

References

    1. Eur J Radiol. 2008 Dec;68(3):385-91 - PubMed
    1. Eur Radiol. 2008 Sep;18(9):1809-17 - PubMed
    1. Circulation. 2008 Jul 29;118(5):586-606 - PubMed
    1. JAMA. 2009 Feb 4;301(5):545-7 - PubMed
    1. Eur Radiol. 2007 Aug;17(8):2028-37 - PubMed

Publication types