Abstract
The continuous measurement of sustained atrial tachyarrhythmia (AT) is now possible with some permanently implanted devices. Data on this subject remain controversial. The aim of this study was to evaluate the incidence of sustained AT in patients treated with cardiac resynchronization therapy using pacemakers without backup defibrillators (CRT-P), within the first year after implantation, using strict definition criteria for sustained AT and a systematic review of all high-quality electrographically recorded episodes. The Mona Lisa study was a prospective, multicenter, cohort study carried out from February 2004 to February 2006, with a 12-month follow-up period. Sustained AT was defined as an episode lasting > or =5 minutes; episodes were confirmed by a systematic review of electrograms in the whole study population. Of the 198 patients who underwent CRT-P device implantation and were enrolled in the study, 173 were in stable sinus rhythm at baseline and were included in the analysis (mean age 70 +/- 9 years, 66% men, 91% in New York Heart Association class III, mean QRS duration 164 +/- 26 ms, mean left ventricular ejection fraction 25 +/- 7%). During a mean follow-up period of 9.9 +/- 3.6 months, 34 patients experienced > or =1 episode of sustained AT, for an incidence rate of 27.5% (95% confidence interval 18.2 to 36.7). Only a history of AT was independently associated with the occurrence of sustained AT within the 12 months after CRT-P device implantation (hazard ratio 2.3, 95% confidence interval 1.2 to 4.4, p = 0.02). In conclusion, this first prospective electrogram-based evaluation of AT incidence demonstrated that 27% of patients developed > or =1 episode of sustained AT lasting > or =5 minutes in the 12 months after CRT-P device implantation.
2010 Elsevier Inc. All rights reserved.
Similar articles
-
Incidence and prognostic significance of sustained ventricular tachycardias in heart failure patients implanted with biventricular pacemakers without a back-up defibrillator: results from the prospective, multicentre, Mona Lisa cohort study.Eur Heart J. 2009 May;30(10):1237-44. doi: 10.1093/eurheartj/ehp071. Epub 2009 Mar 4. Eur Heart J. 2009. PMID: 19264750
-
Results of the multicenter RENEWAL 3 AVT clinical study of cardiac resynchronization defibrillator therapy in patients with paroxysmal atrial fibrillation.J Cardiovasc Electrophysiol. 2006 May;17(5):520-5. doi: 10.1111/j.1540-8167.2006.00440.x. J Cardiovasc Electrophysiol. 2006. PMID: 16684026 Clinical Trial.
-
Long-term retention of cardiac resynchronization therapy.J Am Coll Cardiol. 2004 Jul 7;44(1):72-7. doi: 10.1016/j.jacc.2004.03.054. J Am Coll Cardiol. 2004. PMID: 15234410 Clinical Trial.
-
Prognostic value of electrocardiographic measurements before and after cardiac resynchronization device implantation in patients with heart failure due to ischemic or nonischemic cardiomyopathy.Am J Cardiol. 2008 Feb 1;101(3):359-63. doi: 10.1016/j.amjcard.2007.08.043. Epub 2007 Dec 21. Am J Cardiol. 2008. PMID: 18237600
-
Atrial fibrillation in recipients of cardiac resynchronization therapy device: 1-year results of the randomized MASCOT trial.Am Heart J. 2008 Sep;156(3):520-6. doi: 10.1016/j.ahj.2008.04.013. Epub 2008 Jul 7. Am Heart J. 2008. PMID: 18760135 Clinical Trial.
Cited by
-
Brazilian Guidelines for Cardiac Implantable Electronic Devices - 2023.Arq Bras Cardiol. 2023 Jan 23;120(1):e20220892. doi: 10.36660/abc.20220892. Arq Bras Cardiol. 2023. PMID: 36700596 Free PMC article. English, Portuguese. No abstract available.
-
Advances in Cardiac Resynchronization Therapy.J Innov Card Rhythm Manag. 2019 Jun 15;10(6):3681-3693. doi: 10.19102/icrm.2019.100604. eCollection 2019 Jun. J Innov Card Rhythm Manag. 2019. PMID: 32477735 Free PMC article. Review.
-
Sex differences in device therapy for heart failure: utilization, outcomes, and adverse events.J Womens Health (Larchmt). 2015 Apr;24(4):261-71. doi: 10.1089/jwh.2014.4980. Epub 2015 Mar 20. J Womens Health (Larchmt). 2015. PMID: 25793483 Free PMC article.
-
Cardiac Resynchronization in Patients with Atrial Fibrillation.J Atr Fibrillation. 2015 Dec 31;8(4):1383. doi: 10.4022/jafib.1383. eCollection 2015 Dec. J Atr Fibrillation. 2015. PMID: 27957235 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials