Toward closing the loop: an update on insulin pumps and continuous glucose monitoring systems

Affiliations
Review

Toward closing the loop: an update on insulin pumps and continuous glucose monitoring systems

Tandy Aye et al. Endocrinol Metab Clin North Am. 2010 Sep.

Abstract

This article reviews current pump and continuous glucose monitoring therapy and what will be required to integrate these systems into closed-loop control. Issues with sensor accuracy, lag time, and calibration are discussed as well as issues with insulin pharmacodynamics, which result in a delayed onset of insulin action in a closed-loop system. A stepwise approach to closed-loop therapy is anticipated, where the first systems will suspend insulin delivery based on actual or predicted hypoglycemia. Subsequent systems may control to range, limiting the time spent in hyperglycemia by mitigating the effects of a missed food bolus or underestimate of consumed carbohydrates, while minimizing the risk of hypoglycemia.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Sustained effect of intensive treatment of type 1 diabetes mellitus on development and progression of diabetic nephropathy. the Epidemiology of Diabetes Interventions and Complications (EDIC) study. Jama. 2003;290:2159–67. - PMC - PubMed
    1. Petitti DB, Klingensmith GJ, Bell RA, et al. Glycemic control in youth with diabetes: the SEARCH for diabetes in Youth Study. J Pediatr. 2009;155:668–72. e1–3. - PMC - PubMed
    1. Steil GM, Rebrin K, Darwin C, Hariri F, Saad MF. Feasibility of automating insulin delivery for the treatment of type 1 diabetes. Diabetes. 2006;55:3344–50. - PubMed
    1. The accuracy of the CGMS in children with type 1 diabetes: results of the diabetes research in children network (DirecNet) accuracy study. Diabetes Technol Ther. 2003;5:781–9. - PMC - PubMed
    1. Accuracy of the Modified Continuous Glucose Monitoring (CGMS((R))) Sensor in an Outpatient Setting: Results from a Diabetes Research in Children Network (DirecNet) Study. Diabetes Technol Ther. 2005;7:109–14. - PMC - PubMed

MeSH terms