. 2010 Dec;49(12):2370-4.
doi: 10.1093/rheumatology/keq281. Epub 2010 Aug 19.

Diagnostic performance and validation of autoantibody testing in myositis by a commercial line blot assay

Affiliations

Diagnostic performance and validation of autoantibody testing in myositis by a commercial line blot assay

Anna Ghirardello et al. Rheumatology (Oxford). 2010 Dec.

Abstract

Objective: Serological testing for myositis-specific or associated autoantibodies [myositis-specific antibody (MSA) and myositis-associated antibody (MAA)] is useful for the diagnosis of idiopathic inflammatory myopathies (IIMs). However, available assays are neither standardized nor validated. The objective is to evaluate the accuracy of a commercial line blot assay for myositis diagnosis.

Methods: IgG antibodies against Jo-1, PL-7, PL-12, PM/Scl, Ku, Mi-2 and Ro52 antigens were detected by a line blot and in-house RNA immunoprecipitation or immunoblot. We tested sera from 208 IIM patients, 50 healthy subjects and 180 control patients (11 non-autoimmune myopathy, 23 muscular dystrophy, 11 UCTD, 68 SLE, 36 SSc, 22 SS and 9 arthropathy).

Results: MSAs or MAAs were detected in 98 (47%) out of the 208 IIM patients by line blot: anti-Jo-1 in 43 (21%), anti-PL-7 or anti-PL-12 in 8 (4%), anti-Mi-2 in 9 (4%), anti-PM/Scl in 9 (4%), anti-Ku in 10 (5%) and anti-Ro52 in 49 (24%). Overall specificity was: 100% for anti-Jo-1, anti-PL-7 or PL-12 and anti-PM/Scl; 96% for anti-Ku; 98% for anti-Mi-2; and 76% for anti-Ro52. In-house testing confirmed line blot results regarding anti-Jo-1, anti-PM/Scl and anti-Ku, while it was more accurate than line blot in detecting anti-Mi-2 (7 vs 4% sensitivity, 100 vs 98% specificity), and anti-aminoacyl-tRNA synthetase (anti-ARS) non-Jo-1 antibodies (11 vs 4% sensitivity, 97 vs 99% specificity).

Conclusions: Line blot could be a suitable serological test in the diagnostic workup for myositis, and it represents a reliable alternative to more time-consuming procedures. Continuous effort is recommended in order to improve its accuracy.