Experimental tests of a simple diffusion model for the estimation of scattering and absorption coefficients of turbid media from time-resolved diffuse reflectance measurements
- PMID: 20725319
- DOI: 10.1364/AO.31.003509
Experimental tests of a simple diffusion model for the estimation of scattering and absorption coefficients of turbid media from time-resolved diffuse reflectance measurements
Abstract
When a picosecond light pulse is incident upon a turbid medium such as tissue, the temporal distribution of diffusely reflected and transmitted photons depends on the optical absorption and scattering properties of the medium. From diffusion theory it is possible to derive analytic expressions for the pulse shape in terms of the optical interaction coefficients of a homogeneous semi-infinite medium. Experimental tests of this simple model in tissue-simulating liquid phantoms of different geometries are presented here. The results of these tests show that, in a semi-infinite phantom, the application of the diffusion model provides estimates of the absorption and transport-scattering coefficients that are accurate to better than 10%. Comparable accuracy was also obtained with this simple model for finite slab, cylindrical, and spherical volumes as long as the objects were of sufficient size. For smaller volumes the absorption coefficient was overestimated because of the significant loss of photons at the bounda ries of the object.
Similar articles
-
Time resolved reflectance and transmittance for the non-invasive measurement of tissue optical properties.Appl Opt. 1989 Jun 15;28(12):2331-6. doi: 10.1364/AO.28.002331. Appl Opt. 1989. PMID: 20555520
-
Spatially resolved absolute diffuse reflectance measurements for noninvasive determination of the optical scattering and absorption coefficients of biological tissue.Appl Opt. 1996 May 1;35(13):2304-14. doi: 10.1364/AO.35.002304. Appl Opt. 1996. PMID: 21085367
-
Implementation of a phase array diffuse optical tomographic imager.Rev Sci Instrum. 2008 Aug;79(8):084301. doi: 10.1063/1.2963042. Rev Sci Instrum. 2008. PMID: 19044366
-
Simple and accurate expressions for diffuse reflectance of semi-infinite and two-layer absorbing and scattering media.Appl Opt. 2009 Dec 10;48(35):6670-83. doi: 10.1364/AO.48.006670. Appl Opt. 2009. PMID: 20011007
-
Fully automated spatially resolved reflectance spectrometer for the determination of the absorption and scattering in turbid media.Rev Sci Instrum. 2011 Oct;82(10):103104. doi: 10.1063/1.3648120. Rev Sci Instrum. 2011. PMID: 22047277
Cited by
-
Introduction: feature issue on phantoms for the performance evaluation and validation of optical medical imaging devices.Biomed Opt Express. 2012 Jun 1;3(6):1399-403. doi: 10.1364/BOE.3.001399. Epub 2012 May 15. Biomed Opt Express. 2012. PMID: 22741084 Free PMC article.
-
Numerical simulation of endovenous laser treatment of the incompetent great saphenous vein with external air cooling.Lasers Med Sci. 2013 May;28(3):833-44. doi: 10.1007/s10103-012-1141-0. Epub 2012 Jul 27. Lasers Med Sci. 2013. PMID: 22836189
-
In vitro measurements of optical properties of porcine brain using a novel compact device.Med Biol Eng Comput. 2005 Sep;43(5):658-66. doi: 10.1007/BF02351040. Med Biol Eng Comput. 2005. PMID: 16411639
-
Solid tissue simulating phantoms having absorption at 970 nm for diffuse optics.J Biomed Opt. 2017 Jul 1;22(7):76013. doi: 10.1117/1.JBO.22.7.076013. J Biomed Opt. 2017. PMID: 28727869 Free PMC article.
-
In vivo study of age-related changes in the optical properties of the skin.Lasers Med Sci. 2010 Mar;25(2):269-74. doi: 10.1007/s10103-009-0725-9. Lasers Med Sci. 2010. PMID: 19727920
LinkOut - more resources
Other Literature Sources