A novel broadband impedance method for detection of cell-derived microparticles
Abstract
A novel label-free method is presented to detect and quantify cell-derived microparticles (MPs) by the electrochemical potential-modulated electrochemical impedance spectroscopy (EIS). MPs are present in elevated concentrations during pathological conditions and play a major role in the establishment and pathogenesis of many diseases. Considering this, accurate detection and quantification of MPs is very important in clinical diagnostics and therapeutics. A combination of bulk solution electrokinetic sorting and interfacial impedance responses allows achieving detection limits as low as several MPs per μL. By fitting resulting EIS spectra with an equivalent electrical circuit, the bulk solution electrokinetic and interfacial impedance responses were characterized. In the bulk solution two major relaxations were prominent-β-relaxation in low MHz region due to the MP capacitive membrane bridging, and α-relaxation at ∼10 kHz due to counter ions diffusion. At low frequencies (10-0.1 Hz) at electrochemical potentials exceeding -100 mV, a facile interfacial Faradaic process of oxidation in MPs coupled with diffusion and non-Faradaic double layer charging dominate, probably due to oxidation of phospholipids and/or proteins on the MP surface and MP lysis. Buffer influence on the MP detection demonstrated that a relatively low conductivity Tyrode's buffer background solution is preferential for the MP electrokinetic separation and characterization. This study also demonstrated that standard laboratory methods such as flow cytometry underestimate MP concentrations, especially those with smaller average sizes, by as much as a factor of 2-40.
Copyright © 2010 Elsevier B.V. All rights reserved.
Figures





Similar articles
-
Development of a NanoBioAnalytical platform for "on-chip" qualification and quantification of platelet-derived microparticles.Biosens Bioelectron. 2017 Jul 15;93:250-259. doi: 10.1016/j.bios.2016.08.100. Epub 2016 Aug 29. Biosens Bioelectron. 2017. PMID: 27597127
-
Label-free impedance detection of cancer cells from whole blood on an integrated centrifugal microfluidic platform.Biosens Bioelectron. 2015 Jun 15;68:382-389. doi: 10.1016/j.bios.2014.12.049. Epub 2014 Dec 30. Biosens Bioelectron. 2015. PMID: 25613813
-
Improved detection limits of toxic biochemical species based on impedance measurements in electrochemical biosensors.Biosens Bioelectron. 2010 Oct 15;26(2):923-8. doi: 10.1016/j.bios.2010.06.051. Epub 2010 Jul 3. Biosens Bioelectron. 2010. PMID: 20655726
-
Gateway to understanding microparticles: standardized isolation and identification of plasma membrane-derived vesicles.Nanomedicine (Lond). 2013 Oct;8(10):1657-68. doi: 10.2217/nnm.13.149. Nanomedicine (Lond). 2013. PMID: 24074388 Review.
-
A review of impedance measurements of whole cells.Biosens Bioelectron. 2016 Mar 15;77:824-36. doi: 10.1016/j.bios.2015.10.027. Epub 2015 Oct 22. Biosens Bioelectron. 2016. PMID: 26513290 Review.
Cited by
-
Electrical impedance microflow cytometry with oxygen control for detection of sickle cells.Sens Actuators B Chem. 2018 Feb;255(Pt 2):2392-2398. doi: 10.1016/j.snb.2017.08.163. Epub 2017 Aug 24. Sens Actuators B Chem. 2018. PMID: 29731543 Free PMC article.
-
Extracellular vesicles in cardiovascular disease: are they Jedi or Sith?J Physiol. 2016 Jun 1;594(11):2881-94. doi: 10.1113/JP271336. Epub 2016 Mar 20. J Physiol. 2016. PMID: 26872404 Free PMC article. Review.
-
Electroporation safety factor of 300 nanosecond and 10 millisecond defibrillation in Langendorff-perfused rabbit hearts.PLoS One. 2021 Sep 24;16(9):e0257287. doi: 10.1371/journal.pone.0257287. eCollection 2021. PLoS One. 2021. PMID: 34559811 Free PMC article.
-
Platelet-Derived Extracellular Vesicles as Target of Antiplatelet Agents. What Is the Evidence?Front Pharmacol. 2019 Nov 8;10:1256. doi: 10.3389/fphar.2019.01256. eCollection 2019. Front Pharmacol. 2019. PMID: 31780927 Free PMC article. Review.
-
Protein dielectrophoresis and the link to dielectric properties.Bioanalysis. 2015;7(3):353-71. doi: 10.4155/bio.14.306. Bioanalysis. 2015. PMID: 25697193 Free PMC article. Review.
References
-
- Asami K, Yonezawa T, Wakamatsu H, Koyanagi N. Dielectric spectroscopy of biological cells. Bioelectrochem. Bioelectr. 1996;40:141–145.
-
- Blum A. The possible role of red blood cell microvesicles in atherosclerosis. Eur. J. Intern. Med. 2009;20:101–105. - PubMed
-
- Bothwell TP, Schwan HP. Studies of deionization and impedance spectroscopy for blood analyzer. Nature. 1956;178(4527):265–266. - PubMed
-
- Cocucci E, Racchetti G, Meldolezi J. Shedding microvesicles: artifacts no more. Trends Cell Biol. 2008;19(2):43–51. - PubMed
-
- DiBiasio A, Cametti C. Effect of the dielectric properties of biological cell suspensions. Bioelectrochem. 2007;71(2):149–156. - PubMed
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources