Randomized Controlled Trial
. 2010 Sep;67(3):855-60; discussion 860.
doi: 10.1227/01.NEU.0000374772.22745.C3.

Endovascular treatment of side wall aneurysms using a liquid embolic agent: a US single-center prospective trial

Affiliations
Randomized Controlled Trial

Endovascular treatment of side wall aneurysms using a liquid embolic agent: a US single-center prospective trial

Scott D Simon et al. Neurosurgery. 2010 Sep.

Abstract

Objective: Onyx HD-500 is a liquid embolic agent consisting of ethylene vinyl alcohol copolymer dissolved in dimethylsulfoxide and mixed with tantalum. This viscous embolic agent was designed to treat intracranial side wall aneurysms, but there have been no prospective published series from the United States. From this early experience, we developed several protocol revisions, technical details, and clinical pearls that have not been published for liquid embolic embolization of aneurysms.

Clinical presentation: We present our single-center prospective series of patients treated with Onyx HD-500 from a multicenter, randomized, controlled trial. Thirteen patients received Onyx HD-500, and their ages ranged from 43 to 81 years. Twelve patients had aneurysms on the internal carotid artery, and 1 patient had an aneurysm the vertebral artery. Every patient had an immediate postangiographic result with 90% or more occlusion by an independent core laboratory assessment. In 1 patient, the Onyx HD-500 injection was aborted, and the aneurysm was embolized with coils. Eleven of 13 patients (85%) underwent 6-month follow-up angiography that demonstrated persistent durable occlusion with no recanalization. There was 1 complication (8%) and no deaths.

Conclusion: This is the only prospective series of intracranial aneurysms treated with Onyx HD-500 in the United States. This is also the first publication that describes detailed procedure techniques, recommended protocol revisions, lessons learned from early complications, clinical pearls, and advantages and disadvantages of liquid embolic embolization of aneurysms.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources