"Thicker" polyethylene bearings are associated with higher failure rates in primary total knee arthroplasty
- PMID: 20732620
- DOI: 10.1016/j.arth.2010.04.031
"Thicker" polyethylene bearings are associated with higher failure rates in primary total knee arthroplasty
Abstract
"Thin" modular polyethylene bearings have previously been associated with failure from wear. This study examined the influence of polyethylene thickness on survivorship in primary total knee arthroplasty (TKA). Do "thinner" or "thicker" bearings fail more? Six thousand seventy primary TKAs with a single implant design were reviewed. The failure rate in knees with bearings 14 mm or less was 0.7%, whereas the failure rate of knees with bearings 16 mm or greater was 2.3% (P < .0001; hazard ratio, 3.2). No knee was revised for polyethylene wear. Thicker bearings did not directly cause failure, but factors that lead to the insertion of a thicker bearing such as a deeper tibial resection and ligament imbalance may contribute to the observed increased failure. The significant influence of this often-unrecognized surgical variable has not been previously reported and must be carefully considered during TKA.
Copyright 2010. Published by Elsevier Inc.
Similar articles
-
Primary posterior cruciate-retaining total knee arthroplasty: a comparison of American and Japanese cohorts.J Surg Orthop Adv. 2007 Winter;16(4):164-70. J Surg Orthop Adv. 2007. PMID: 18053397
-
"Thicker" Polyethylene Bearings Are Not Associated With Higher Failure Rates in Primary Total Knee Arthroplasty.J Arthroplasty. 2018 Sep;33(9):2810-2814. doi: 10.1016/j.arth.2018.04.026. Epub 2018 Apr 23. J Arthroplasty. 2018. PMID: 29773277
-
[Medin modular implant for total knee arthroplasty--mid-term results].Acta Chir Orthop Traumatol Cech. 2009 Feb;76(1):30-4. Acta Chir Orthop Traumatol Cech. 2009. PMID: 19268046 Czech.
-
Mobile-bearing total knee arthroplasty: design factors in minimizing wear.Clin Orthop Relat Res. 2006 Nov;452:70-7. doi: 10.1097/01.blo.0000238776.27316.d6. Clin Orthop Relat Res. 2006. PMID: 16924175 Review.
-
Polyethylene Wear in Knee Arthroplasty.J Knee Surg. 2015 Oct;28(5):370-5. doi: 10.1055/s-0035-1551833. Epub 2015 Jun 1. J Knee Surg. 2015. PMID: 26030263 Review.
Cited by
-
Robotic-Assisted Total Knee Arthroplasty Improves Accuracy and Reproducibility of the Polyethylene Insert Thickness Compared to Manual Instrumentation or Navigation: A Retrospective Cohort Study.Arthroplast Today. 2024 Oct 16;30:101489. doi: 10.1016/j.artd.2024.101489. eCollection 2024 Dec. Arthroplast Today. 2024. PMID: 39492997 Free PMC article.
-
No difference in the use of revision components and rerevision rate in conversion to total knee replacement following Oxford Partial Knee Microplasty Instrumentation: a registry study of 529 conversions.Acta Orthop. 2023 Jul 31;94:387-392. doi: 10.2340/17453674.2023.15310. Acta Orthop. 2023. PMID: 37519250 Free PMC article.
-
Effect of Obesity on Component Alignment in Total Knee Arthroplasty.Ochsner J. 2018 Fall;18(3):226-229. doi: 10.31486/toj.18.0005. Ochsner J. 2018. PMID: 30275786 Free PMC article.
-
Better accuracy of robotic-assisted total knee arthroplasty compared to conventional technique in patients with failed high tibial osteotomy.PLoS One. 2024 Nov 11;19(11):e0313391. doi: 10.1371/journal.pone.0313391. eCollection 2024. PLoS One. 2024. PMID: 39527607 Free PMC article.
-
Appropriately planned resection depth can impact outcomes after robotic total knee arthroplasty.J Orthop. 2025 Mar 10;69:42-46. doi: 10.1016/j.jor.2025.03.004. eCollection 2025 Nov. J Orthop. 2025. PMID: 40162048