A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output
- PMID: 20736431
- DOI: 10.1213/ANE.0b013e3181f08a5b
A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output
Abstract
Numerous cardiac output (CO) monitors have been produced that provide continuous rather than intermittent readings. Bland and Altman has become the standard method for validating their performance against older standards. However, the Bland and Altman method only assesses precision and does not assess how well a device detects serial changes in CO (trending ability). Currently, there is no consensus on how trending ability, or trend analysis, should be performed. Therefore, we performed a literature review to identify articles published between 1997 and 2009 that compared methods of continuous CO measurement. Identified articles were grouped according to measurement technique and statistical methodology. Articles that analyzed trending ability were reviewed with the aim of finding an acceptable statistical method. Two hundred two articles were identified. The most popular methods were pulse contour (69 articles), Doppler (54), bioimpedance (38), and transpulmonary or continuous thermodilution (27). Forty-one articles addressed trending, and of these only 23 provided an in-depth analysis. Several common statistical themes were identified: time plots, regression analysis, Bland and Altman using change in CO (ΔCO), and the 4-quadrant plot, which used direction of change of ΔCO to determine the concordance. This plot was further refined by exclusion of data when values were small. Receiver operating characteristic curves were used to define the exclusion zone. In animal studies, a reliable reference standard such as an aortic flowprobe was frequently used, and regression or time plots could be used to show trending. Clinical studies were more problematic because data collection points were fewer (8-10 per subject). The consensus was to use the 4-quadrant plot with exclusion zones and apply concordance analysis. A concordance rate of >92% when using a 15% zone indicated good trending. A new method of presenting trend data (ΔCO) on a polar plot is proposed. Agreement was shown by the angle with the horizontal axis and ΔCO by the distance from the center. Trending can be assessed by the vertical limits of the data, similar to the Bland and Altman method.
Similar articles
-
Assessment of trending ability of cardiac output monitors by polar plot methodology.J Cardiothorac Vasc Anesth. 2011 Jun;25(3):536-46. doi: 10.1053/j.jvca.2011.01.003. Epub 2011 Mar 17. J Cardiothorac Vasc Anesth. 2011. PMID: 21419654
-
The Ability of esCCO and ECOM Monitors to Measure Trends in Cardiac Output During Alveolar Recruitment Maneuver After Cardiac Surgery: A Comparison with the Pulmonary Thermodilution Method.Anesth Analg. 2015 Aug;121(2):383-91. doi: 10.1213/ANE.0000000000000753. Anesth Analg. 2015. PMID: 25902321
-
Noninvasive continuous cardiac output by the Nexfin before and after preload-modifying maneuvers: a comparison with intermittent thermodilution cardiac output.Anesth Analg. 2013 Aug;117(2):366-72. doi: 10.1213/ANE.0b013e31829562c3. Epub 2013 Jun 11. Anesth Analg. 2013. PMID: 23757471
-
Cardiac output monitoring: a contemporary assessment and review.Crit Care Med. 2015 Jan;43(1):177-85. doi: 10.1097/CCM.0000000000000608. Crit Care Med. 2015. PMID: 25251758 Review.
-
Estimation of cardiac output variations induced by hemodynamic interventions using multi-beat analysis of arterial waveform: a comparative off-line study with transesophageal Doppler method during non-cardiac surgery.J Clin Monit Comput. 2022 Apr;36(2):501-510. doi: 10.1007/s10877-021-00679-z. Epub 2021 Mar 9. J Clin Monit Comput. 2022. PMID: 33687601 Free PMC article. Review.
Cited by
-
Agreement between stroke volume measured by oesophageal Doppler and uncalibrated pulse contour analysis during fluid loads in severe aortic stenosis.J Clin Monit Comput. 2015 Aug;29(4):435-41. doi: 10.1007/s10877-015-9666-y. Epub 2015 Feb 1. J Clin Monit Comput. 2015. PMID: 25638514
-
Continuous glucose monitoring on the ICU using a subcutaneous sensor.Med Klin Intensivmed Notfmed. 2015 Jun;110(5):360-3. doi: 10.1007/s00063-014-0453-1. Epub 2015 Feb 14. Med Klin Intensivmed Notfmed. 2015. PMID: 25676120
-
Evaluating corrected carotid flow time as a non-invasive parameter for trending cardiac output and stroke volume in cardiac surgery patients.J Ultrasound. 2023 Mar;26(1):89-97. doi: 10.1007/s40477-022-00678-z. Epub 2022 Apr 9. J Ultrasound. 2023. PMID: 35397758 Free PMC article.
-
Non-invasive cardiac output measurement with electrical velocimetry in patients undergoing liver transplantation: comparison of an invasive method with pulmonary thermodilution.BMC Anesthesiol. 2018 Oct 2;18(1):138. doi: 10.1186/s12871-018-0600-y. BMC Anesthesiol. 2018. PMID: 30285627 Free PMC article.
-
A preliminary study evaluating cardiac output measurement using Pressure Recording Analytical Method (PRAM) in anaesthetized dogs.BMC Vet Res. 2018 Mar 6;14(1):72. doi: 10.1186/s12917-018-1392-5. BMC Vet Res. 2018. PMID: 29510691 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical