Withdrawing intra-aortic balloon pump support paradoxically improves microvascular flow

Affiliations

Withdrawing intra-aortic balloon pump support paradoxically improves microvascular flow

Luuk D H Munsterman et al. Crit Care. 2010.

Abstract

Introduction: The Intra-Aortic Balloon Pump (IABP) is frequently used to mechanically support the heart. There is evidence that IABP improves microvascular flow during cardiogenic shock but its influence on the human microcirculation in patients deemed ready for discontinuing IABP support has not yet been studied. Therefore we used sidestream dark field imaging (SDF) to test our hypothesis that human microcirculation remains unaltered with or without IABP support in patients clinically ready for discontinuation of mechanical support.

Methods: We studied 15 ICU patients on IABP therapy. Measurements were performed after the clinical decision was made to remove the balloon catheter. We recorded global hemodynamic parameters and performed venous oximetry during maximal IABP support (1:1) and 10 minutes after temporarily stopping the IABP therapy. At both time points, we also recorded video clips of the sublingual microcirculation. From these we determined indices of microvascular perfusion including perfused vessel density (PVD) and microvascular flow index (MFI).

Results: Ceasing IABP support lowered mean arterial pressure (74 ± 8 to 71 ± 10 mmHg; P = 0.048) and increased diastolic pressure (43 ± 10 to 53 ± 9 mmHg; P = 0.0002). However, at the level of the microcirculation we found an increase of PVD of small vessels <20 μm (5.47 ± 1.76 to 6.63 ± 1.90; P = 0.0039). PVD for vessels >20 μm and MFI for both small and large vessels were unaltered. During the procedure global oxygenation parameters (ScvO2/SvO2) remained unchanged.

Conclusions: In patients deemed ready for discontinuing IABP support according to current practice, SDF imaging showed an increase of microcirculatory flow of small vessels after ceasing IABP therapy. This observation may indicate that IABP impairs microvascular perfusion in recovered patients, although this warrants confirmation.

PubMed Disclaimer

Figures

Figure 1
Figure 1
A screenshot from a typical example of the human sublingual microcirculation using SDF imaging.
Figure 2
Figure 2
The effect of IABP on perfused vessel density (PVD) for vessels <20 μm. The perfused vessel density increased significantly, 5.47 ± 1.76 to 6.63 ± 1.90 (P = 0.0039), 10 minutes after IABP switch-off.

Comment in

References

    1. Trost JC, Hillis LD. Intra-aortic balloon counterpulsation. Am J Cardiol. 2006;97:1391–1398. doi: 10.1016/j.amjcard.2005.11.070. - DOI - PubMed
    1. Santa-Cruz RA, Cohen MG, Ohman EM. Aortic counterpulsation: a review of the hemodynamic effects and indications for use. Catheter Cardiovasc Interv. 2006;67:68–77. doi: 10.1002/ccd.20552. - DOI - PubMed
    1. Nanas JN, Moulopoulos SD. Counterpulsation: historical background, technical improvements, hemodynamic and metabolic effects. Cardiology. 1994;84:156–167. doi: 10.1159/000176394. - DOI - PubMed
    1. Elbers PW, Ince C. Mechanisms of critical illness--classifying microcirculatory flow abnormalities in distributive shock. Crit Care. 2006;10:221. doi: 10.1186/cc4969. - DOI - PMC - PubMed
    1. Mathura KR, Vollebregt KC, Boer K, De Graaff JC, Ubbink DT, Ince C. Comparison of OPS imaging and conventional capillary microscopy to study the human microcirculation. J Appl Physiol. 2001;91:74–78. - PubMed

LinkOut - more resources