Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Dec;36(6 Pt 1):450-4.
doi: 10.1016/j.diabet.2010.05.004. Epub 2010 Aug 23.

A new simple method for assessing sudomotor function: relevance in type 2 diabetes

Affiliations

A new simple method for assessing sudomotor function: relevance in type 2 diabetes

H Mayaudon et al. Diabetes Metab. 2010 Dec.

Abstract

Aim: The current sudomotor function tests are too time-consuming to be used for diabetic patients in daily practice. EZSCAN is a new, patented technology that measures electrochemical skin conductance (ESC) through reverse iontophoresis and chronoamperometry. The aim of the present study was to assess the sensitivity, specificity and reproducibility of the method in type 2 diabetic patients in comparison to control subjects with no risk of diabetes.

Methods: A total of 133 type 2 diabetic patients and 41 control subjects were tested. Participants placed their hands and feet on nickel electrodes, and an incremental low direct current was applied to the anode for 2 min. ESC was calculated from the resulting voltage and generated current. ESC diagnostic accuracy was analyzed by ROC curve modeling, and reproducibility was assessed using Bland-Altman analysis.

Results: The ESC of hands and feet was significantly reduced in diabetic patients (53±16μSi and 67±14μSi, respectively) compared with control subjects (68±16μSi and 80±7μSi, respectively; P<0.0001). ESC values had a sensitivity of 75% and specificity of 100%, with an area under the ROC curve of 0.88 at a threshold of 50% on the EZSCAN scale. Coefficients of variation in hand and foot measurements were 15 and 7%, respectively.

Conclusion: The good sensitivity, specificity and reproducibility of EZSCAN make it a feasible alternative for assessing sudomotor dysfunction, a clinical manifestation of autonomic neuropathy in diabetic patients. The test takes<3 min to perform, and requires neither special patient preparation nor medical personnel training.

PubMed Disclaimer

Publication types

MeSH terms