. 1990 Nov;33(11):681-7.
doi: 10.1007/BF00400570.

Underestimation of glucose turnover determined using [6-3H]glucose tracer in non-steady state. The role of a tritiated tracer impurity

Affiliations

Underestimation of glucose turnover determined using [6-3H]glucose tracer in non-steady state. The role of a tritiated tracer impurity

R D Neely et al. Diabetologia. 1990 Nov.

Abstract

The use of tritiated glucose tracers may result in underestimation of glucose turnover during hyperinsulinaemic clamps giving paradoxical negative endogenous glucose production rates. While mathematical modelling errors in the analysis of tracer data are major determinants of this underestimate in the non-steady state, the relative importance of tracer contamination under these conditions remains in doubt. We have used high performance liquid chromatography to assess the possible contribution to this problem of a labelled tracer impurity found in [6-3H]glucose. In conventional 4 h hyperinsulinaemic clamps performed in six normal subjects, labelled impurity increased as a percentage of the neutral plasma radioactivity fraction from 5.3 +/- 0.9% after a 2 h equilibration period (0 min) to 13.5 +/- 2.2% at 120 min and 15.4 +/- 2.4% at 240 min, as plasma glucose specific activities fell following the infusion of insulin. Negative endogenous glucose production rates were observed both at 90-120 min (-8.8 +/- 1.6 mumol.kg-1min-1) and at 210-240 min (-8.5 +/- 1.4 mumol.kg-1min-1) implying a persistent underestimate in isotopically determined glucose appearance rate. Using chromatography data to correct for impurity increased glucose appearance rates by 7.9 +/- 2.1% at 120 min and 11.0 +/- 2.5% at 240 min. Purified tracer was then used for a further six clamps. When the conventional protocol was used with unlabelled glucose infusion an obvious negative error persisted only at 90-120 min. In contrast, labelled infusions gave exclusively positive values for endogenous glucose production.(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Clin Invest. 1986 Dec;78(6):1479-86 - PubMed
    1. Am J Physiol. 1989 Oct;257(4 Pt 1):E531-40 - PubMed
    1. Endocr Rev. 1985 Winter;6(1):45-86 - PubMed
    1. Diabetes. 1981 Oct;30(10):829-35 - PubMed
    1. Am J Physiol. 1956 Sep;187(1):15-24 - PubMed

Publication types