Reduction of the negative influence of patient motion on quality of CBCT scan
- PMID: 20800973
- DOI: 10.1016/j.mehy.2010.07.046
Reduction of the negative influence of patient motion on quality of CBCT scan
Abstract
The role of cone beam computed tomography (CBCT) in imaging of the oral and maxillofacial region is well known and its indications and possibilities are still increasing. More sophisticated technologies are being developed each year, mainly providing higher resolution, bigger field of view, faster scanning and better scatter reduction. One of the major problems remaining to be solved is the unwanted movement of the patient during the scanning procedure. All hardware solutions that have been developed to fix the patient's head in a steady position have their limits. For example, they cannot eliminate small movements caused by breathing, heartbeat, and swallowing. We have developed a simple method to improve these CBCT images. The movement of the scanned object is monitored with marks attached to it. These marks are identified on every 2D image captured during the scanning procedure and used to unify the position of these 2D images. The final 3D reconstruction produces a sharper 3D data set with higher resolution and reduced blur. In conclusion, this simple method has the potential to improve the quality of CBCT scans.
Copyright © 2010 Elsevier Ltd. All rights reserved.
Similar articles
-
A motion-compensated cone-beam CT using electrical impedance tomography imaging.Physiol Meas. 2011 Jan;32(1):19-34. doi: 10.1088/0967-3334/32/1/002. Epub 2010 Nov 19. Physiol Meas. 2011. PMID: 21098909
-
Scatter kernel estimation with an edge-spread function method for cone-beam computed tomography imaging.Phys Med Biol. 2008 Dec 7;53(23):6729-48. doi: 10.1088/0031-9155/53/23/006. Epub 2008 Nov 7. Phys Med Biol. 2008. PMID: 18997269
-
On cone-beam computed tomography artifacts induced by titanium implants.Clin Oral Implants Res. 2010 Jan;21(1):100-7. doi: 10.1111/j.1600-0501.2009.01817.x. Epub 2009 Oct 21. Clin Oral Implants Res. 2010. PMID: 19845706
-
Shading correction algorithm for improvement of cone-beam CT images in radiotherapy.Phys Med Biol. 2008 Oct 21;53(20):5719-33. doi: 10.1088/0031-9155/53/20/010. Epub 2008 Sep 26. Phys Med Biol. 2008. PMID: 18824785
-
Spatial resolution in CBCT machines for dental/maxillofacial applications-what do we know today?Dentomaxillofac Radiol. 2015;44(1):20140204. doi: 10.1259/dmfr.20140204. Dentomaxillofac Radiol. 2015. PMID: 25168812 Free PMC article. Review.
Cited by
-
Head motion and perception of discomfort by young children during simulated CBCT examinations.Dentomaxillofac Radiol. 2021 Mar 1;50(3):20200445. doi: 10.1259/dmfr.20200445. Epub 2020 Oct 30. Dentomaxillofac Radiol. 2021. PMID: 33125282 Free PMC article. Clinical Trial.
-
Patient movement characteristics and the impact on CBCT image quality and interpretability.Dentomaxillofac Radiol. 2018 Jan;47(1):20170216. doi: 10.1259/dmfr.20170216. Epub 2017 Oct 20. Dentomaxillofac Radiol. 2018. PMID: 28872352 Free PMC article.
-
An ex vivo study of automated motion artefact correction and the impact on cone beam CT image quality and interpretability.Dentomaxillofac Radiol. 2018 Jul;47(5):20180013. doi: 10.1259/dmfr.20180013. Epub 2018 Mar 22. Dentomaxillofac Radiol. 2018. PMID: 29537303 Free PMC article.
-
Repetition Rate of Scanning Due to Motion Artefacts in Cone-Beam Computed Tomography: a Retrospective Study.J Oral Maxillofac Res. 2024 Mar 31;15(1):e6. doi: 10.5037/jomr.2024.15106. eCollection 2024 Jan-Mar. J Oral Maxillofac Res. 2024. PMID: 38812948 Free PMC article.
-
Cone beam computed tomography in paediatric dentistry: overview of recent literature.Eur Arch Paediatr Dent. 2013 Jun;14(3):131-40. doi: 10.1007/s40368-013-0029-4. Eur Arch Paediatr Dent. 2013. PMID: 23564647 Review.
MeSH terms
LinkOut - more resources
Full Text Sources