Changes in the optical properties (at 632.8 nm) of slowly heated myocardium
- PMID: 20802699
- DOI: 10.1364/AO.32.000367
Changes in the optical properties (at 632.8 nm) of slowly heated myocardium
Abstract
The three transport equation optical properties, the absorption coefficient, the scattering coefficient, and the average cosine of the scattering angle, or anisotropy factor have been measured (at 632.8 nm) for canine myocardium after it is heated in a water bath at room temperature and at 37-75 degrees C for 1000 s. The measurement system was a double integrating sphere with collimated light and utilized the adding-doubling solution to the equation of radiative transfer. The absorption coefficient (room temperature control, 2.0 +/- 0.4 cm(-1)) began to increase and the anisotropy factor (room temperature control, 0.93 +/- 0.02) to decrease at above 45 degrees C. At 75 degrees C the changes were significant at the p < 0.0005 level (absorption, 4.5 +/- 1.3 cm(-1); anisotropy, 0.78 +/- 0.05). There was no significant change in the scattering coefficient (room temperature controls, 161 +/- 33 cm(-1)).
Similar articles
-
Optical properties of normal and carcinomatous bronchial tissue.Appl Opt. 1994 Nov 1;33(31):7397-405. doi: 10.1364/AO.33.007397. Appl Opt. 1994. PMID: 20941301
-
Double-integrating-sphere system for measuring the optical properties of tissue.Appl Opt. 1993 Feb 1;32(4):399-410. doi: 10.1364/AO.32.000399. Appl Opt. 1993. PMID: 20802704
-
Changes in the absorption and scattering properties in the near-infrared region during the growth of Bacillus subtilis in liquid culture.Appl Spectrosc. 2009 Jan;63(1):25-32. doi: 10.1366/000370209787169777. Appl Spectrosc. 2009. PMID: 19146716
-
Continuous changes in the optical properties of liver tissue during laser-induced interstitial thermotherapy.Lasers Surg Med. 2001;28(4):307-12. doi: 10.1002/lsm.1054. Lasers Surg Med. 2001. PMID: 11344509
-
Inverse hybrid technique for determining the optical properties of turbid media from integrating-sphere measurements.Appl Opt. 1996 Dec 1;35(34):6797-809. doi: 10.1364/AO.35.006797. Appl Opt. 1996. PMID: 21151265
Cited by
-
Dual-wavelength photoacoustic technique for monitoring tissue status during thermal treatments.J Biomed Opt. 2013 Jun;18(6):067003. doi: 10.1117/1.JBO.18.6.067003. J Biomed Opt. 2013. PMID: 23733048 Free PMC article.
-
Changes in tissue optical properties due to radio-frequency ablation of myocardium.Med Biol Eng Comput. 2003 Jul;41(4):403-9. doi: 10.1007/BF02348082. Med Biol Eng Comput. 2003. PMID: 12892362
-
Monitoring system for investigating the effect of temperature change on optical properties.Lasers Med Sci. 2018 Nov;33(8):1763-1768. doi: 10.1007/s10103-018-2537-2. Epub 2018 Jun 2. Lasers Med Sci. 2018. PMID: 29858971
-
Autofluorescence hyperspectral imaging of radiofrequency ablation lesions in porcine cardiac tissue.J Biophotonics. 2017 Aug;10(8):1008-1017. doi: 10.1002/jbio.201600071. Epub 2016 Aug 22. J Biophotonics. 2017. PMID: 27545317 Free PMC article.
-
Modified optical coefficient measurement system for bulk tissue using an optical fiber insertion with varying field of view and depth at the fiber tip.Lasers Med Sci. 2019 Oct;34(8):1613-1618. doi: 10.1007/s10103-019-02756-x. Epub 2019 Mar 13. Lasers Med Sci. 2019. PMID: 30868317