. 2011 Feb;21(2):326-36.
doi: 10.1007/s00330-010-1924-2. Epub 2010 Aug 29.

Iodine contrast iso-attenuating with diagnostic gadolinium doses in CTA and angiography results in ultra-low iodine doses. A way to avoid both CIN and NSF in azotemic patients?

Affiliations

Iodine contrast iso-attenuating with diagnostic gadolinium doses in CTA and angiography results in ultra-low iodine doses. A way to avoid both CIN and NSF in azotemic patients?

Ulf Nyman et al. Eur Radiol. 2011 Feb.

Abstract

Objectives: To establish iodine (I) contrast medium (CM) doses iso-attenuating with gadolinium (Gd) CM doses regarded diagnostic in CTA and percutaneous catheter-angiography/vascular interventions (PCA/PVI) in azotemic patients.

Methods: CT Hounsfield units (HU) were measured in 20-mL syringes containing 0.01/0.02,/0.05/0.1 mmol/mL of iodine or gadolinium atoms and placed in phantoms. Relative contrast were measured in 20-mL syringes filled with iohexol at 35/50/70/90/110/140 mg I/mL and 0.5 M gadodiamide using radiofluoroscopy (RF), digital radiography (DX) and x-ray angiography (XA) systems. Clinical doses of Gd-CM at CTA/PCA/PVI were reviewed.

Results: At CT 91-116 and 104-125 mg I/mL in the chest and abdominal phantoms, respectively, were iso-attenuating with 0.5 M Gd at 80-140 kVp. At RF/DX/XA systems 35-90 mg I/mL were iso-attenuating with 0.5 M gadodiamide at 60-115 kVp. Clinically, 60 mL 91-125 mg I/mL (5.5-7.5 gram-iodine) at 80-140 kVp CTA and 60 mL of 35-90 mg I/mL (2.1-5.4 gram-iodine) at 60-115 kVp PCA/PVI would be iso-attenuating with 60 mL 0.5 M Gd-CM (=0.4 mmol Gd/kg in a 75-kg person).

Conclusions: Meticulous examination technique and judicious use of ultra-low I-CM doses iso-attenuating with diagnostic Gd-CM doses in CTA and PCA/PVI may minimise the risk of nephrotoxicity in azotemic patients, while there is no risk of NSF.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Radiology. 1998 Jun;207(3):657-62 - PubMed
    1. J Interv Cardiol. 2005 Oct;18(5):379-83 - PubMed
    1. Med Phys. 1993 Jan-Feb;20(1):15-31 - PubMed
    1. J Comput Assist Tomogr. 1999 Nov-Dec;23(6):939-40 - PubMed
    1. Radiology. 2008 Apr;247(1):88-97 - PubMed

MeSH terms