A retrospective analysis of pedicle screws in contact with the great vessels
- PMID: 20809738
- DOI: 10.3171/2010.3.SPINE09657
A retrospective analysis of pedicle screws in contact with the great vessels
Abstract
Object: Pedicle screws placed in the thoracic, lumbar, and sacral spine occasionally come in contact with the aorta, vena cava, or iliac vessels. When such screws are seen on postoperative imaging in an asymptomatic patient, the surgeon must decide whether it is riskier to revise the screw or to observe it. The authors hypothesized that the incidence of screw placement causing perioperative vessel injury is low and, further, that screws placed in contact with major vessels do not always result in vessel injury.
Methods: A retrospective review of the operative records of 182 consecutive patients undergoing thoracic, lumbar, and lumbosacral pedicle screw fusion was performed to determine the frequency of intraoperative vessel injury. Postoperative imaging for 107 patients was available to determine the incidence of screws in contact with major vessels. Charts were examined to determine if any adverse sequelae had resulted from malpositioned screws. Patient outcomes were documented.
Results: There were no intraoperative vessel injuries or deaths in 182 consecutive operations. One hundred seven patients with available postoperative films had 680 pedicle screws placed between T-3 and the sacrum during 115 operations. No patient had arterial screw penetration or deformation on postoperative imaging. Thirty-three of the 680 inserted screws were in contact with a major vessel on routine postoperative imaging. The contacted vessels included the aorta (4 cases), the iliac artery (7 cases), and the iliac veins (22 cases). Patients were followed up until death or November 2009, for a mean follow-up of 44 months (median 44 months, range 5-109 months). None of the patients with vessel contact was noted to suffer symptoms or sequelae as a result of vessel contact. Radiographic follow-up as long as 50 months after surgery revealed no detectable vessel abnormality at the contacted site.
Conclusions: Placing pedicle screws in contact with major vessels is a known risk of spinal surgery. The risk of repositioning a screw in contact with a major vessel but causing no symptoms must be weighed against the relative risk of leaving it in place.
Comment in
-
Pedicle screws and great vessels.J Neurosurg Spine. 2010 Sep;13(3):401-2; discussion 402. doi: 10.3171/2010.2.SPINE1044. J Neurosurg Spine. 2010. PMID: 20809737 No abstract available.
Similar articles
-
Incidence and clinical significance of vascular encroachment resulting from freehand placement of pedicle screws in the thoracic and lumbar spine: analysis of 6816 consecutive screws.Spine (Phila Pa 1976). 2014 Apr 15;39(8):683-7. doi: 10.1097/BRS.0000000000000221. Spine (Phila Pa 1976). 2014. PMID: 24480963
-
Three-dimensional image-guided placement of S2 alar screws to adjunct or salvage lumbosacral fixation.Spine J. 2010 Jul;10(7):595-601. doi: 10.1016/j.spinee.2010.03.023. Spine J. 2010. PMID: 20434406
-
Accuracy and safety of pedicle screw placement in neuromuscular scoliosis with free-hand technique.Eur Spine J. 2008 Dec;17(12):1686-96. doi: 10.1007/s00586-008-0795-6. Epub 2008 Oct 1. Eur Spine J. 2008. PMID: 18830636 Free PMC article.
-
Malpositioned pedicle screw in spine deformity surgery endangering the aorta: report of two cases, review of literature, and proposed management algorithm.Spine Deform. 2020 Aug;8(4):809-817. doi: 10.1007/s43390-020-00094-5. Epub 2020 Mar 13. Spine Deform. 2020. PMID: 32170660 Review.
-
Clinically relevant complications related to pedicle screw placement in thoracolumbar surgery and their management: a literature review of 35,630 pedicle screws.Neurosurg Focus. 2011 Oct;31(4):E8. doi: 10.3171/2011.7.FOCUS11168. Neurosurg Focus. 2011. PMID: 21961871 Review.
Cited by
-
COMBINED ENDOVASCULAR REPAIR OF AORTA AND REMOVAL OF PENETRATING PEDICLE SCREW AFTER POSTERIOR INSTRUMENTATION: A CASE REPORT AND LITERATURE REVIEW.Acta Clin Croat. 2024 Oct;63(2):422-430. doi: 10.20471/acc.2024.63.02.20. Acta Clin Croat. 2024. PMID: 40104226 Free PMC article. Review.
-
Severe major vessel injury during peadicle screw removal: a case report.Front Surg. 2023 Jun 13;10:1187801. doi: 10.3389/fsurg.2023.1187801. eCollection 2023. Front Surg. 2023. PMID: 37383382 Free PMC article.
-
The Optimal Screw Length of Lumbar Pedicle Screws during Minimally Invasive Surgery Fixation: A Computed Tomography-Guided Evaluation of 771 Screws.Asian Spine J. 2019 Dec;13(6):936-941. doi: 10.31616/asj.2018.0276. Epub 2019 Jul 17. Asian Spine J. 2019. PMID: 31309769 Free PMC article.
-
Clinical Application and Curative Effect Analysis of Postural Awareness Surgical Tool Assisted Nail Placement in Adolescent Idiopathic Scoliosis.Orthop Surg. 2024 May;16(5):1109-1116. doi: 10.1111/os.14038. Epub 2024 Mar 20. Orthop Surg. 2024. PMID: 38509016 Free PMC article.
-
Use of the Universal Clamp in adolescent idiopathic scoliosis for deformity correction and as an adjunct to fusion: 2-year follow-up.J Child Orthop. 2011 Aug;5(4):273-82. doi: 10.1007/s11832-011-0357-z. Epub 2011 Jul 13. J Child Orthop. 2011. PMID: 22852033 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources