Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2010 Dec;24(6):966-9.
doi: 10.1007/s00540-010-1016-0. Epub 2010 Sep 2.

Comparisons of two different doses of fentanyl for procedural analgesia during epidural catheter placement: a double-blind prospective, randomized, placebo-controlled study

Affiliations
Randomized Controlled Trial

Comparisons of two different doses of fentanyl for procedural analgesia during epidural catheter placement: a double-blind prospective, randomized, placebo-controlled study

Takeshi Yano et al. J Anesth. 2010 Dec.

Abstract

The purpose of this study was to investigate the effect of fentanyl on analgesic properties and respiratory responses during an epidural procedure. Sixty patients premedicated with oral brotizolam 0.25 mg were allocated to receive procedural analgesia with saline or 25 or 50 μg of fentanyl. Five minutes after administration, an epidural procedure was started. Pain assessments were made immediately after the epidural catheter placement using a visual analog scale. The lowest SpO₂ levels during the procedure were recorded to evaluate respiratory depression, and cardiovascular complications were also recorded. The pain scores were significantly lower in the 25 and 50 μg fentanyl groups than in the placebo group (P < 0.01). There was no difference in pain assessment between the 25 and 50 μg fentanyl groups. The lowest SpO₂ value of the 50 μg fentanyl group was significantly lower than those of the other groups (P < 0.001). Seven of 20 cases in the 50 μg fentanyl group needed oxygen administration because of a decreased SpO₂ value (<94%). No cardiovascular complications were observed in any group during the entire study period. Thus, intravenous fentanyl at a dose of 25 μg provides effective procedural analgesia without the risk of hypoxemia during an epidural procedure in a patient with preanesthetic medication.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Anesthesiology. 1990 Dec;73(6):1091-102 - PubMed
    1. Anesth Prog. 2005 Fall;52(3):95-101 - PubMed
    1. Anesth Analg. 2003 Jun;96(6):1547-1552 - PubMed
    1. Pain. 1990 Oct;43(1):69-79 - PubMed
    1. J Clin Monit Comput. 2007 Oct;21(5):295-302 - PubMed

Publication types

MeSH terms

LinkOut - more resources