Practical approaches to four-dimensional heavy-charged-particle lung therapy

Affiliations
Clinical Trial

Practical approaches to four-dimensional heavy-charged-particle lung therapy

Shinichiro Mori et al. Radiol Phys Technol. 2010 Jan.

Abstract

We have developed new design algorithms for compensating boli to facilitate the implementation of four-dimensional charged-particle lung therapy in clinical applications. Four-dimensional CT (4DCT) data for eight lung cancer patients were acquired with a 16-slice CT under free breathing. Six compensating boli were developed that may be categorized into three classes: (1) boli-based on contoured gross tumor volumes (GTV) from a 4DCT data set during each respiratory phase, subsequently combined into one (GTV-4DCT bolus); (2) boli-based on contoured internal target volume (ITV) from image-processed 3DCT data only [temporal-maximum-intensity-projection (TMIP)/temporal-average-intensity-projection (TAIP)] with calculated boli (ITV-TMIP and ITV-TAIP boli); and (3) boli-based on contoured ITV utilizing image-processed 3DCT data, applied to 4DCT for design of boli for each phase, which were then combined. The carbon beam dose distribution within each bolus was calculated as a function of time and compared to plans in which respiratory-ungated/gated strategies were used. The GTV-4DCT treatment plan required a prohibitively long time for contouring the GTV manually for each respiratory phase, but it delivered more than 95% of the prescribed dose to the target volume. The TMIP and TAIP treatments, although more time-efficient, resulted in an unacceptable excess dose to normal tissues and underdosing of the target volume. The dose distribution for the ITV-4DCT bolus was similar to that for the GTV-4DCT bolus and required significantly less practitioner time. The ITV-4DCT bolus treatment plan is time-efficient and provides a high-quality dose distribution, making it a practical alternative to the GTV-4DCT bolus treatment plan.

PubMed Disclaimer

References

    1. Med Phys. 2005 Apr;32(4):942-51 - PubMed
    1. Int J Radiat Oncol Biol Phys. 2000 Nov 1;48(4):1015-24 - PubMed
    1. Med Phys. 1982 Sep-Oct;9(5):749-52 - PubMed
    1. Int J Radiat Oncol Biol Phys. 1999 Jan 15;43(2):437-45 - PubMed
    1. Med Phys. 2004 Feb;31(2):333-40 - PubMed

Publication types

LinkOut - more resources