Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Apr;29(4):751-62.
doi: 10.1002/etc.104.

Sampling in the Great Lakes for pharmaceuticals, personal care products, and endocrine-disrupting substances using the passive polar organic chemical integrative sampler

Affiliations

Sampling in the Great Lakes for pharmaceuticals, personal care products, and endocrine-disrupting substances using the passive polar organic chemical integrative sampler

Hongxia Li et al. Environ Toxicol Chem. 2010 Apr.

Abstract

The passive polar organic chemical integrative sampler in the pharmaceutical configuration (i.e., pharmaceutical-POCIS) was calibrated for sampling at water temperatures of 5, 15 and 25 degrees C to determine the influence of temperature on chemical-specific sampling rates (R(S)), thus providing more robust estimates of the time-weighted average concentrations of pharmaceuticals and personal care products (PPCPs) and endocrine-disrupting substances (EDS) in surface water. The effect of water temperature and flow on the R(S) of these analytes was evaluated in the laboratory with a static system. The loss of the test compounds from water by uptake into POCIS was linear over an 8-d period, and these experimental data yielded R(S) values in the range of 0.07 to 2.46 L/d across the temperature range for the 30 compounds tested. Water temperature and flow influenced POCIS uptake rates, but these effects were relatively small, which is consistent with the theory for uptake into POCIS samplers. Therefore, under a narrow range of water temperatures and flows, it may not be necessary to adjust the R(S) for POCIS. Except for acidic drugs and sulfonamide antibiotics, R(S) values were positively correlated with octanol-water partition coefficients (log K(OW)) of the test compounds. A linear relationship was also observed between R(S) and chromatographic retention times on a C18 reversed-phase column. These observations may provide a rapid method for estimating the R(S) of additional chemicals in the POCIS. The application of the R(S) to POCIS deployed for one month in Lake Ontario, Canada, during the summers of 2006 and 2008 yielded estimates of PPCP and EDS concentrations that are consistent with conventional concentration measurements of these compounds in Lake Ontario surface water.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms