Radiologists' perceptions of computer aided detection versus double reading for mammography interpretation
- PMID: 20832024
- PMCID: PMC3149895
- DOI: 10.1016/j.acra.2010.05.007
Radiologists' perceptions of computer aided detection versus double reading for mammography interpretation
Abstract
Rationale and objectives: The aim of this study was to examine radiologists' use and perceptions of computer-aided detection (CAD) and double reading for screening mammography interpretation.
Materials and methods: A mailed survey of 257 community radiologists participating in the national Breast Cancer Surveillance Consortium was used to assess perceptions and practices related to CAD and double reading. Latent class analysis was used to classify radiologists' overall perceptions of CAD and double reading on the basis of their agreement or disagreement with specific statements about CAD and double reading.
Results: Most radiologists (64%) reported using CAD for more than half the screening mammograms they interpreted, but only <5% reported double reading that much. More radiologists perceived that double reading improved cancer detection rates compared to CAD (74% vs 55% reported), whereas fewer radiologists thought that double reading decreased recall rates compared to CAD (50% vs 65% reported). Radiologists with the most favorable perceptions of CAD were more likely to think that CAD improved cancer detection rates without taking too much time compared to radiologists with the most unfavorable overall perceptions. In latent class analysis, an overall favorable perception of CAD was significantly associated with the use of CAD (81%), a higher percentage of workload in screening mammography (80%), academic affiliation (71%), and fellowship training (58%). Perceptions of double reading that were most favorable were associated with academic affiliation (98%).
Conclusions: Radiologists' perceptions were more favorable toward double reading by a second clinician than by a computer, although fewer used double reading in their own practice. The majority of radiologists perceived both CAD and double reading at least somewhat favorably, although for largely different reasons.
Copyright © 2010 AUR. Published by Elsevier Inc. All rights reserved.
Figures




References
-
- Birdwell RL, Bandodkar P, Ikeda DM. Computer-aided detection with screening mammography in a university hospital setting. Radiology. 2005;236(2):451–457. - PubMed
-
- National Cancer Institute. [accessed July 2009];Computer-Aided Interpretation of Mammograms: Questions and Answers. 2007 http://www.cancer.gov/newscenter/pressreleases/CADmammographyQandA.
-
- Taylor P, Potts HW. Computer aids and human second reading as interventions in screening mammography: two systematic reviews to compare effects on cancer detection and recall rate. Eur J Cancer. 2008;44(6):798–807. - PubMed
-
- Freer TW, Ulissey MJ. Screening mammography with computer-aided detection: prospective study of 12,860 patients in a community breast center. Radiology. 2001;220(3):781–6. - PubMed
-
- Houssami N, Given-Wilson R, Ciatto S. Early detection of breast cancer: overview of the evidence on computer-aided detection in mammography screening. J Med Imaging Radiat Oncol. 2009;53(2):171–6. - PubMed
Publication types
MeSH terms
Grants and funding
- U01 CA063740/CA/NCI NIH HHS/United States
- U01CA69976/CA/NCI NIH HHS/United States
- U01 CA070040/CA/NCI NIH HHS/United States
- U01CA70013/CA/NCI NIH HHS/United States
- U01CA63736/CA/NCI NIH HHS/United States
- U01CA86082/CA/NCI NIH HHS/United States
- K05 CA104699/CA/NCI NIH HHS/United States
- 1R01 CA107623/CA/NCI NIH HHS/United States
- U01CA70040/CA/NCI NIH HHS/United States
- U01CA63740/CA/NCI NIH HHS/United States
- R01 CA107623/CA/NCI NIH HHS/United States
- U01 CA086082/CA/NCI NIH HHS/United States
- U01 CA063731/CA/NCI NIH HHS/United States
- U01 CA086076/CA/NCI NIH HHS/United States
- U01 CA069976/CA/NCI NIH HHS/United States
- U01CA86076/CA/NCI NIH HHS/United States
- U01 CA063736/CA/NCI NIH HHS/United States
- 1K05 CA104699/CA/NCI NIH HHS/United States
- U01 CA070013/CA/NCI NIH HHS/United States
- U01CA63731/CA/NCI NIH HHS/United States
LinkOut - more resources
Full Text Sources
Miscellaneous