Three-dimensional display of myocardial perfusion: detection of ischemic lesions using a new image subtraction method
- PMID: 2083544
- DOI: 10.1007/BF00819405
Three-dimensional display of myocardial perfusion: detection of ischemic lesions using a new image subtraction method
Abstract
A recent, commercially available computer program for the three-dimensional (3D) display of single-photon emission tomography (SPET) data was used to study myocardial perfusion in patients with coronary artery disease (CAD). To enable the detection of small ischemic lesions, the authors proposed a new "distance-substraction" method: after suitable centering of the axial slices, 3D "distance-shaded" images of the stress study were subtracted from the corresponding views of the rest study. With this technique, small changes in surface-to-observer distance were highlighted, thus enabling us to detect nontransmural ischemic areas of the myocardium. General characteristics and possibilities of the subtraction technique were tested on a simple myocardial phantom. Some clinical results of the application of this method on CAD patients are presented and discussed. In CAD patients in whom only nontransmural ischemic lesions are present, the subtraction of "distance-shaded" images is decisive for a correct diagnosis.
Similar articles
-
Myocardial perfusion imaging with technetium-99m sestamibi SPECT in the evaluation of coronary artery disease.Am J Cardiol. 1990 Oct 16;66(13):55E-62E. doi: 10.1016/0002-9149(90)90613-6. Am J Cardiol. 1990. PMID: 2145748 Review.
-
[Myocardial scintigraphy with Tc-99m-MIBI for assessing the extent and severity of coronary disease: a comparison with thallium-201 and equilibrium angiocardioscintigraphy].G Ital Cardiol. 1993 Feb;23(2):127-38. G Ital Cardiol. 1993. PMID: 8491353 Italian.
-
Simultaneous measurement of myocardial perfusion and ventricular function during exercise from a single injection of technetium-99m sestamibi in coronary artery disease.Am J Cardiol. 1990 Oct 16;66(13):68E-71E. doi: 10.1016/0002-9149(90)90615-8. Am J Cardiol. 1990. PMID: 2145749
-
Fluorine-18 deoxyglucose PET for assessment of viable myocardium in perfusion defects in 99mTc-MIBI SPET: a comparative study in patients with coronary artery disease.Eur J Nucl Med. 1992;19(5):334-42. doi: 10.1007/BF00177055. Eur J Nucl Med. 1992. PMID: 1612095
-
The new 99mTc myocardial perfusion imaging agents: 99mTc-sestamibi and 99mTc-teboroxime.Circulation. 1991 Sep;84(3 Suppl):I7-21. Circulation. 1991. PMID: 1832100 Review.
Cited by
-
Surface rendering of three-dimensional myocardial SPECT: clinical usefulness compared with bull's-eye and conventional tomograms.J Nucl Cardiol. 1997 Sep-Oct;4(5):349-57. doi: 10.1016/s1071-3581(97)90025-8. J Nucl Cardiol. 1997. PMID: 9362010
-
Clinical application of three-dimensional myocardial imaging: evaluation of efficacy of medical treatment on myocardial perfusion.Ann Nucl Med. 1996 Nov;10(4):383-9. doi: 10.1007/BF03164798. Ann Nucl Med. 1996. PMID: 9006722
-
Quantitative analysis in single photon emission tomography (SPET).Eur J Nucl Med. 1992;19(1):47-61. doi: 10.1007/BF00178308. Eur J Nucl Med. 1992. PMID: 1547808 Review.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Miscellaneous