Risk factors for corneal inflammatory and mechanical events with extended wear silicone hydrogel contact lenses
- PMID: 20838352
- DOI: 10.1097/OPX.0b013e3181f6f97d
Risk factors for corneal inflammatory and mechanical events with extended wear silicone hydrogel contact lenses
Abstract
Purpose: To identify risk factors for contact lens-related corneal inflammatory events and mechanical events in wearers of silicone hydrogel lenses on a 30-night extended wear (EW) schedule in India.
Methods: An interventional study with 188 subjects wearing silicone hydrogel lenses bilaterally on a 30-night EW schedule. Subjects were dispensed with lenses and reviewed at scheduled visits up to 6 months of EW. Multivariate logistic regression, after adjusting for within subject correlation, was used to develop the statistical model.
Results: Occupations in non-ideal environments were found to predispose a lens wearer to inflammatory events (p = 0.003). Wearers in the non-ideal group, who had varying degrees of exposure to ocular irritants in their work environment had highest incidence of inflammatory events (19.2%). Wearers in a controlled, ideal environment had lowest levels of events (3.3%). Students occupied a position between the two groups (9.3%). Inflammatory rate was higher among wearers with increased microbial contamination of lenses (p = 0.002). Wearers with an inflammatory event had mean colony forming unit of 1.97 log compared with mean colony forming unit of 1.45 log in group with no inflammatory event. Corneal vascularization was associated with the development of inflammatory events (p = 0.001) with 50% of wearers with vascularization experiencing events compared with 7.6% of subjects with no vascularization. Reduced lens movement was associated with inflammatory events with subjects more likely to develop inflammatory events compared with those wearers with optimal lens movement (p = 0.027).
Conclusions: A multitude of factors, including environmental influences, lens contamination, ocular characteristics, and lens fit, contributes to the development of inflammatory events, information that is of clinical relevance to practitioners worldwide. Occupational environment was also a contributory factor, confirming that a duty of clinicians is to ascertain the nature of the work environment of lens wearers (and potential wearers) and to balance the needs of the wearer with the potential risks.
Similar articles
-
Inflammatory and mechanical complications associated with 3 years of up to 30 nights of continuous wear of lotrafilcon A silicone hydrogel lenses.Eye Contact Lens. 2007 Jul;33(4):191-5. doi: 10.1097/ICL.0b013e31802cc275. Eye Contact Lens. 2007. PMID: 17630627 Clinical Trial.
-
Objective and subjective responses in patients refitted to daily-wear silicone hydrogel contact lenses.Optom Vis Sci. 2006 Oct;83(10):758-68. doi: 10.1097/01.opx.0000237547.35542.b8. Optom Vis Sci. 2006. PMID: 17041322 Clinical Trial.
-
The incidence of microbial keratitis among wearers of a 30-day silicone hydrogel extended-wear contact lens.Ophthalmology. 2005 Dec;112(12):2172-9. doi: 10.1016/j.ophtha.2005.09.014. Ophthalmology. 2005. PMID: 16325711
-
The epidemiology of microbial keratitis with silicone hydrogel contact lenses.Eye Contact Lens. 2013 Jan;39(1):79-85. doi: 10.1097/ICL.0b013e3182713919. Eye Contact Lens. 2013. PMID: 23172318 Review.
-
An early assessment of silicone hydrogel safety: pearls and pitfalls, and current status.Eye Contact Lens. 2007 Nov;33(6 Pt 2):358-61; discussion 362-3. doi: 10.1097/ICL.0b013e318157c77f. Eye Contact Lens. 2007. PMID: 17975420 Review.
Cited by
-
Biometric risk factors for corneal neovascularization associated with hydrogel soft contact lens wear in Korean myopic patients.Korean J Ophthalmol. 2014 Aug;28(4):292-7. doi: 10.3341/kjo.2014.28.4.292. Epub 2014 Jul 22. Korean J Ophthalmol. 2014. PMID: 25120337 Free PMC article.
-
Inter-visit measurement variability of conjunctival vasculature and circulation in habitual contact lens wearers and non-lens wearers.Eye Vis (Lond). 2019 Apr 1;6:10. doi: 10.1186/s40662-019-0135-4. eCollection 2019. Eye Vis (Lond). 2019. PMID: 30984795 Free PMC article.
-
Risk factors for contact lens-induced papillary conjunctivitis associated with silicone hydrogel contact lens wear.Eye Contact Lens. 2014 May;40(3):117-22. doi: 10.1097/ICL.0000000000000019. Eye Contact Lens. 2014. PMID: 24681609 Free PMC article.
-
Effect of Antimicrobial Contact Lenses on Corneal Infiltrative Events: A Randomized Clinical Trial.Transl Vis Sci Technol. 2021 Jun 1;10(7):32. doi: 10.1167/tvst.10.7.32. Transl Vis Sci Technol. 2021. PMID: 34191016 Free PMC article. Clinical Trial.
-
The State of the Art about Etiopathogenetic Models on Breast Implant Associated-Anaplastic Large Cell Lymphoma (BIA-ALCL): A Narrative Review.J Clin Med. 2021 May 12;10(10):2082. doi: 10.3390/jcm10102082. J Clin Med. 2021. PMID: 34066230 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources