Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 Dec;78(12):1305-11.
doi: 10.1038/ki.2010.321. Epub 2010 Sep 15.

Cystatin C is not a better estimator of GFR than plasma creatinine in the general population

Affiliations
Free article
Comparative Study

Cystatin C is not a better estimator of GFR than plasma creatinine in the general population

Bjørn O Eriksen et al. Kidney Int. 2010 Dec.
Free article

Abstract

Accurate measurement of glomerular filtration rate (GFR) is complicated and costly; therefore, GFR is commonly estimated by assessing creatinine or cystatin C concentrations. Because estimates based on cystatin C predict cardiovascular disease better than creatinine, these estimates have been hypothesized to be superior to those based on creatinine, when the GFR is near the normal range. To test this, we measured GFR by iohexol clearance in a representative sample of middle-aged (50-62 years) individuals in the general population, excluding those with coronary heart or kidney disease, stroke or diabetes mellitus. Bias, precision (median and interquartile range of estimated minus measured GFR (mGFR)), and accuracy (percentage of estimates within 30% of mGFR) of published cystatin C and creatinine-based GFR equations were compared in a total of 1621 patients. The cystatin C-based equation with the highest accuracy (94%) had a bias of 3.5 and precision of 18 ml/min per 1.73 m², whereas the most accurate (95%) creatinine-based equation had a bias of 2.9 and precision of 15 ml/min per 1.73 m² The best equation, based on both cystatin C and creatinine, had a bias of 7.6 ml/min per 1.73 m², precision of 15 ml/min per 1.73 m², and accuracy of 92%. Thus, estimates of GFR based on cystatin C were not superior to those based on creatinine in the general population. Hence, the better prediction of cardiovascular disease by cystatin C than creatinine measurements, found by others, may be due to factors other than GFR.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources